Pinpoint Test BD : U0140:00
- Normal Operation and Fault Conditions
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition IPC U0140:00 Lost Communication With Body Control Module: No Sub Type Information Sets on-demand and in continuous memory in the IPC if data messages received from the BCM over the HS-CAN are missing. Possible Sources
- Communication concern
- Battery voltage concern
- BCM
- IPC
- BD1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify there is an observable symptom present.
Is an observable symptom present?
Yes GO to BD2 No The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. CLEAR the DTC. - BD2 CHECK THE COMMUNICATION NETWORK
- Using a diagnostic scan tool, perform a Network Test.
Does the BCM pass the network test?
Yes GO to BD3 No REFER to: Communications Network . - BD3 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE BCM (BODY CONTROL MODULE) SELF-TEST
- Using a diagnostic scan tool, perform the BCM module self-test.
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Body Control Module (BCM) . No GO to BD4 - BD4 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Using a diagnostic scan tool, perform the IPC self-test.
Is DTC U3006:16 or DTC U3006:17 recorded?
Yes For DTC U3006:16, GO to Pinpoint Test BK For DTC U3006:17, GO to Pinpoint Test BL No GO to BD5 - BD5 RECHECK THE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)NOTE: If new modules were installed prior to the DTC being set, the module configuration can be incorrectly set during the PMI or the PMI may not have been carried out.
- Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Using a diagnostic scan tool, perform the IPC self-test.
Is DTC U0140:00 still present?
Yes GO to BD6 No The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. CLEAR the DTC. - BD6 CHECK FOR DTC (DIAGNOSTIC TROUBLE CODE) U0140:00 SET IN OTHER MODULES
- Using a diagnostic scan tool, clear all Diagnostic Trouble Codes (DTCs).
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Using a diagnostic scan tool, retrieve all continuous memory Diagnostic Trouble Codes (DTCs).
Is DTC U0140:00 set in other modules on the network?
Yes REFER to The BCM Does Not Respond To The Diagnostic Scan Tool to DIAGNOSE the CAN circuits. REFER to: Communications Network . No GO to BD7 - BD7 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connector. Make sure it seats and latches correctly.
- Operate the system and verify the concern is still present
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Guided Routine Testing . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.