LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2018 >> Transit-350 Base, Van Cargo Extended, 3.2L Eng VIN V >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Engine Controls - Powertrain DTC Charts & Descriptions (Except Diesel & Hybrid)) >> Diagnostic Trouble Code (DTC) Charts and Descriptions >> DTC P0403 - EGR A Control Circuit/Open

DTC P0403 - EGR A Control Circuit/Open

WARNING: This page is about a different variant/trim than selected.
P0403 - EGR A CONTROL CIRCUIT/OPEN

Description:  The exhaust gas recirculation (EGR) system is continuously monitored to check the four electric EGR motor coils, circuits, and the PCM for opens, shorts to voltage and ground. If a concern is detected, the EGR system is disabled and additional monitoring is suspended for the remainder of the drive until the next drive cycle.
Possible Causes: 
  • Electric EGR stepper motor windings open
  • Electric EGR connector not seated correctly
  • EGRMC circuit open
  • EGRMC circuit short to voltage
  • EGRMC circuit short to ground
  • Damaged PCM
Diagnostic Aids: 
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST KD .