DTC P1408 - EGR Flow Out Of Self Test Range
P1408 - EGR FLOW OUT OF SELF TEST RANGE
| For Vehicles With DPFEGR | |||
| Description: | This test is carried out during the key ON, engine running (KOER) on demand self test only. The exhaust gas recirculation (EGR) system is commanded on at a fixed engine speed. This DTC sets when the measured EGR flow falls above or below the required calibration. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | |||
| For Vehicles With An Electric EGR | |||
| Description: | This test is carried out during the key ON, engine running (KOER) on demand self test only. The exhaust gas recirculation (EGR) system is commanded on at a fixed engine speed. This DTC sets when the measured EGR flow falls above or below the required calibration. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Use the output state control function of the scan tool and monitor the MAP and the EGRMDSD PIDs while commanding the EEGR on. If EGR is introduced into the engine at idle, the RPM drops or stalls out. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| F-150 2.7L, F-150 3.3L |
GO to PINPOINT TEST HE . | ||
| Escape/Kuga 2.5L, Fusion 2.5L, Transit Connect |
GO to PINPOINT TEST KD . | ||