Home >> Ford >> 2018 >> Transit Connect XL, Van Cargo >> Repair and Diagnosis >> Electrical >> Gauges >> Information Center - Instrumentation, Message Center And Warning Chimes >> Diagnosis And Testing >> Instrumentation, Message Center and Warning Chimes >> Pinpoint Tests >> Pinpoint Test At : U0100:00 >> Pinpoint Test At : U0100:00

Pinpoint Test At : U0100:00

  1. AT1 VERIFY THE SCAN TOOL COMMUNICATES WITH THE PCM (POWERTRAIN CONTROL MODULE)

    • Ignition ON.

    • Connect a diagnostic scan tool.

    • Check that a vehicle session can be established using a diagnostic scan tool.

    Can a vehicle session be established? 

    Yes  GO to  AT2
    No  REFER to: Communications Network .
  2. AT2 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) CONTINUOUS MEMORY DIAGNOSTIC TROUBLE CODES (DTCS)

    • Using a diagnostic scan tool, perform the IPC self-test.

    • Clear the Diagnostic Trouble Codes (DTCs).

    • Wait 10 seconds.

    • Repeat the IPC self-test.

    Is DTC U0100:00 retrieved again? 

    Yes  GO to  AT3
    No  The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
  3. AT3 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE PCM (POWERTRAIN CONTROL MODULE) KOEO (KEY ON, ENGINE OFF) SELF-TEST

    • Using a diagnostic scan tool, perform the PCM KOEO self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Electronic Engine Controls .
    No  GO to  AT4
  4. AT4 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST

    • Using a diagnostic scan tool, perform the IPC self-test.

    Are any Diagnostic Trouble Codes (DTCs) other than DTC U0100:00 recorded? 

    Yes  REFER to DTC Chart: IPC .
    No  GO to  AT5
  5. AT5 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE BCM (BODY CONTROL MODULE) SELF-TEST

    • Using a diagnostic scan tool, perform the BCM self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Body Control Module (BCM) .
    No  GO to  AT6
  6. AT6 CHECK FOR DTC (DIAGNOSTIC TROUBLE CODE) U0100:00 SET IN OTHER MODULES

    • Using a diagnostic scan tool, clear all Diagnostic Trouble Codes (DTCs).

    • Ignition OFF.

    • Ignition ON.

    • Wait 10 seconds.

    • Using a diagnostic scan tool, perform the continuous memory self-test.

    • Retrieve the Continuous Memory Diagnostic Trouble Codes (CMDTCs) from all modules.

    Is DTC U0100:00 set in other modules on the network? 

    Yes  GO to  AT7
    No  GO to  AT8
  7. AT7 CHECK FOR CORRECT PCM (POWERTRAIN CONTROL MODULE) OPERATION

    • Ignition OFF.

    • Disconnect and inspect all PCM connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the PCM connectors. Make sure they seat and latch correctly.

    • Operate the system and verify the concern is still present

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to PCM Guided Routine Testing .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.
  8. AT8 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION

    • Ignition OFF.

    • Disconnect and inspect the IPC connector.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the IPC connector. Make sure it seats and latches correctly.

    • Operate the system and verify the concern is still present

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Guided Routine Testing .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.