Home >> Ford >> 2018 >> Taurus Limited, FWD, Gas >> Repair and Diagnosis >> External Pages >> Different car >> Section 32 (Climate Control System - General Information (2 Of 2)) >> Diagnosis And Testing >> Climate Control System - Vehicles With: Electronic Automatic Temperature Control (EATC) >> Pinpoint Tests >> Pinpoint Test M : B1B71:11, B1B71:15

Pinpoint Test M : B1B71:11, B1B71:15

WARNING: This page is about a different car, the 2018 Ford EcoSport. However, it is still accessible from the selected car via links, so may be relevant.
  1. Automatic Climate Control System for schematic and connector information.

    Normal Operation and Fault Conditions 

    The evaporator temperature sensor, REFER to: Climate Control System - Vehicles With: Electronic Automatic Temperature Control (EATC) - System Operation and Component Description .

    DTC Fault Trigger Conditions 

    DTC Description Fault Trigger Condition
    HVAC B1B71:11 Evaporator Temperature Sensor: Circuit Short To Ground The HVAC control module senses lower than expected voltage on the sensor feedback circuit, indicating a short to ground.
    HVAC B1B71:15 Evaporator Temperature Sensor: Circuit Short To Battery Or Open The HVAC control module senses greater than expected voltage on the sensor feedback circuit, indicating a short to voltage, an open circuit or sensor.

    Possible Sources 

    • Wiring, terminals or connectors
    • Evaporator temperature sensor
    • HVAC control module

  2. NOTE: Use the correct probe adapter(s) when making measurements. Failure to. Use the correct probe adapter(s) may damage the connector.
  3. M1 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO VOLTAGE

    • Ignition OFF.

    • Disconnect HVAC control module C294A.

    • Disconnect Evaporator temperature sensor C296.

    • Ignition ON.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C296-1
      GFD328094Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C296-2
      GFD328094Courtesy of FORD MOTOR COMPANY
      Ground

    Is any voltage present? 

    Yes  REPAIR the circuit.
    No  GO to  M2
  4. M2 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO GROUND

    • Ignition OFF.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C296-1
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C296-2
      GFD328095Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance greater than 10, 000 ohms? 

    Yes  GO to  M3
    No  REPAIR the circuit.
  5. M3 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C296-1
      GFD328095Courtesy of FORD MOTOR COMPANY
      Refer to C294A-19
      Refer to C296-2
      GFD328095Courtesy of FORD MOTOR COMPANY
      Refer to C294A-2

    Is the resistance less than 3 ohms? 

    Yes  GO to  M4
    No  REPAIR the circuit.
  6. M4 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TOGETHER

    • Ignition OFF.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C296-1
      GFD328095Courtesy of FORD MOTOR COMPANY
      Refer to C296-2

    Is the resistance less than 10, 000 ohms? 

    Yes  INSTALL a new evaporator temperature sensor. REFER to: Evaporator Temperature Sensor . TEST the system for normal operation. If the concern is still present, GO to  M5
    No  REPAIR the circuits.
  7. M5 CHECK FOR CORRECT HVAC (HEATING, VENTILATION AND AIR CONDITIONING) CONTROL MODULE OPERATION

    • Ignition OFF.

    • Disconnect and inspect all HVAC control module electrical connectors (if not previously disconnected).

    • Repair:

      • corrosion (install new connector or terminal - clean module pins)
      • damaged or bent pins - install new terminals or pins
      • pushed-out pins - install new pins as necessary

    • Connect all HVAC control module electrical connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW the TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new HVAC control module. REFER to: Heating, Ventilation and Air Conditioning (HVAC) Control Module .
    No  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.