Operating with Remote Keyless Entry (RKE)
The pedals can be adjusted using the RKE transmitter with the ignition in OFF, ON, ACC or RUN; but the gear selector must be in the PARK position. When the RKE button is pressed on the IA key, the transmitted signal is received by the TPM module. The TPM module sends a message to the RFA along a hard wired LIN. The RFA then sends the message to the BCM over the MS-CAN. The BCM acts as a gateway module and transmits the message over the HS-CAN to the SCCM. The SCCM then provides voltage to the adjustable pedal motor to move the pedals to the position programmed into the IA key.
The SCCM monitors the Hall-effect sensor in the adjustable pedal motor and stops sending voltage to the motor when the required pedal position is reached. If the SCCM receives a pedal position input from the adjustable pedals control switch during a memory position recall, the module stops the memory recall and responds to the new pedal position input.