LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2018 >> Fusion Sport >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System (Battery, Battery Mounting And Battery Cables) - Fusion (Except Hybrid) >> General Procedures >> Battery Disconnect and Connect

Battery Disconnect and Connect

Disconnect 

NOTE: Removing the negative battery ground cable at the LH strut tower will not disable the vehicle's electrical system.
NOTE: When the battery is disconnected and connected, some abnormal drive symptoms may occur while the vehicle relearns its adaptive strategy. The charging system set point may also vary. The vehicle may need to be driven to relearn its strategy.

Vehicles with Auto-Start-Stop System 

  1. Remove the air cleaner. Refer to: Air Cleaner .

    All vehicles 

  2. Remove the bolt and the battery hold-down bracket.

    Torque: 89 lb.in (10 Nm)

    GFD195809Courtesy of FORD MOTOR COMPANY
  3. Position the battery.
    GFD195810Courtesy of FORD MOTOR COMPANY
  4. NOTE: If equipped with a battery monitoring sensor, be careful not to damage the sensor when removing the terminal from the battery post. Do not pry on the terminals or component damage may occur.
    NOTE: Battery cable displayed without a battery monitoring sensor, battery cable with a battery monitoring sensor similar.
    NOTE: When disconnecting the battery cable to interrupt power to the vehicle electrical system, disconnect the battery ground cable only. It is not necessary to disconnect the positive battery cable.

    1. Loosen the nut and position the negative battery cable.

      Torque: 44 lb.in (5 Nm)

    2. Position the positive battery cable cover, loosen the nut and position the positive battery cable.

      Torque: 44 lb.in (5 Nm)

GFD195811Courtesy of FORD MOTOR COMPANY

Connect 

  1. To install, reverse the removal procedure.