Rear Thermostatic Expansion Valve: Removal

NOTE: Removal steps in this procedure may contain installation details.
  1. Recover the refrigerant. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging .
  2. Remove the LH front seat. Refer to: Front Seat .
  3. Remove the second row double seat. Refer to: Second Row Double Seat .
  4. Position aside the LH loadspace trim panel.
    GFD215555Courtesy of FORD MOTOR COMPANY
    • Position aside the rear door weather-strip and the safety belt.

    • Remove the retainers and the rear scuff plate trim panel.

    GFD215764Courtesy of FORD MOTOR COMPANY
  5. Position aside the front door weather-strip, release the clips and remove the front door scuff plate trim panel.
    GFD215757Courtesy of FORD MOTOR COMPANY
    • Remove the safety belt anchor bolt and position aside the safety belt and the rear door weather-strip.

      Torque: 30 lb.ft (40 Nm)

    • Release the clips, slide up and remove the lower B-pillar trim panel.

    GFD215765Courtesy of FORD MOTOR COMPANY
  6. Remove the retainers and position aside the front floor carpet. Use the General Equipment: Retaining Strap
    GFD215781Courtesy of FORD MOTOR COMPANY
    • Remove the retainers and the duct.

    • Remove the front floor B-pillar LH spacer.

    GFD215767Courtesy of FORD MOTOR COMPANY
  7. Remove the retainers and the A/C auxiliary assembly cover.
    GFD215768Courtesy of FORD MOTOR COMPANY
    • Remove the retainers.

    • Detach the tabs and then remove the rear thermostatic expansion valve cover.

    GFD215769Courtesy of FORD MOTOR COMPANY
  8. NOTE: Make sure that all openings are sealed.

    • Remove the rear evaporator rear outlet and inlet line fitting nut.

    • Detach the LH and RH rear floor ducts.

    • Remove the bolts, nut and position aside the rear climate control housing.

      Torque: 71 lb.in (8 Nm)

    GFD215790Courtesy of FORD MOTOR COMPANY
  9. NOTE: Make sure that all openings are sealed.

    Disconnect the electrical connector, detach the retainer, remove the bolts and the rear thermostatic expansion valve.

    Torque: 35 lb.in (4 Nm)

GFD215791Courtesy of FORD MOTOR COMPANY