Home >> Ford >> 2017 >> Transit Connect XLT, Van Passenger >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Controls - Powertrain DTC Charts & Descriptions (Except Diesel & Hybrid) - DTC P060A - P2005 >> Diagnostic Trouble Code (DTC) Charts And Descriptions >> P2005 - Intake Manifold Runner Control Stuck Open (Bank 2)

P2005 - Intake Manifold Runner Control Stuck Open (Bank 2)

P2005 - INTAKE MANIFOLD RUNNER CONTROL STUCK OPEN (BANK 2)

Description:  This DTC sets when the intake manifold runner control (IMRC) is commanded closed and the intake manifold runner control bank 2 (IMRC2) sensor indicates the IMRC is open.
Possible Causes: 
  • IMRC2 circuit short to voltage
  • IMRC2 circuit short to SIGRTN
  • IMRC2 circuit short to ground
  • Damaged IMRC actuator
  • Damaged IMRC solenoid
  • Blocked vacuum hoses
  • Damaged PCM
Diagnostic Aids:  The IMRC2 sensor value should change when the IMRC is commanded open or closed.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to Pinpoint Test HU .