| 0-15% |
Invalid OFF duty cycle. |
The fuel pump control module sends a 20% duty cycle signal on the FPM circuit. The fuel pump is OFF. |
| 37% |
Normal low speed operation. |
The fuel pump control module operates the fuel pump at the speed requested. The fuel pump control module sends a 60% duty cycle signal on the FPM circuit. |
| 47% |
Normal high speed operation. |
The fuel pump control module operates the fuel pump at the speed requested. The fuel pump control module sends a 60% duty cycle signal on the FPM circuit. |
| 51-67% |
Invalid ON duty cycle. |
The fuel pump control module sends a 20% duty cycle signal on the FPM circuit. The fuel pump is OFF. |
| 67-83% |
Valid OFF duty cycle. |
The fuel pump control module sends a 60% duty cycle signal on the FPM circuit. The fuel pump is OFF. |
| 83-100% |
Invalid ON duty cycle. |
The fuel pump control module sends a 20% duty cycle signal on the FPM circuit. The fuel pump is OFF. |