Pinpoint Test I : DTCS P0748, P0960, P0961, P0962, P0963: Notes
Refer to Transmission Controls - MPS6 for schematic and connector information.
Normal Operation and Fault Conditions
The PCM controls the hydraulic line pressure by varying the amount of current applied to the LPC solenoid. When no current is applied to the LPC Solenoid, the LPC Solenoid is fully opened, resulting in the maximum amount of hydraulic pressure to the main pressure regulator valve. When maximum current is applied, the LPC Solenoid is fully closed, resulting in minimum pressure to the main pressure regulator valve.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P0748 | LPC Solenoid Electrical | LPC solenoid electrical circuit general fault. May set along with DTC P0960, P0962 and P0963. |
| P0960 | LPC Solenoid Control Circuit/Open | Open circuit in solenoid or solenoid circuitry. |
| P0961 | LPC Solenoid Control Circuit Range/Performance | Intermittent short to ground in solenoid or solenoid circuitry. |
| P0962 | LPC Solenoid Control Circuit Low | Short to ground in solenoid or solenoid circuitry. |
| P0963 | LPC Solenoid Control Circuit High | Short to power in solenoid circuitry. |
Possible Sources
- Connectors damaged or pushed-out terminals, corrosion, loose wires and missing or damaged seals
- LPC Solenoid
- Transmission internal wiring harness frame
- PCM