P0100 - Mass Or Volume Air Flow Sensor A Circuit
P0100 - MASS OR VOLUME AIR FLOW SENSOR A CIRCUIT
| Description: | This DTC sets when the mass airflow (MAF) sensor frequency changes below a minimum calibrated limit for greater than 0.5 seconds. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Install a new mass airflow/intake air temperature (MAF/IAT) sensor. Refer to the Service Information, Electronic Engine Controls. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | Refer to the Description, Possible Causes and Diagnostic Aids for the DTC. | ||