Park Position Detect Switch
The park position detect switch is hardwired to the IPC through a single signal circuit. The park position detect switch is hardwired to a separate ground circuit through the selector lever. The IPC provides a reference voltage to the park position detect switch. When the selector lever is in PARK (P), the park position detect switch opens to ground, sending the reference voltage high. When the selector lever is moved out of PARK (P), the park position detect switch routes the reference voltage to ground, pulling the circuit low to the IPC.