Wastegate Control Valve Solenoid: Removal
- Remove the air cleaner outlet pipe LH. Refer to: Air Cleaner Outlet Pipe LH .
-
- Loosen the wastegate control valve solenoid hose clamp and then disconnect the wastegate control valve solenoid hose from the vacuum pump. Use the General Equipment: Hose Clamp Remover/Installer
- Detach the hose retainer from the studbolt.
- Detach the wire harness retainer from the studbolt.
- Disconnect the wastegate control valve solenoid hoses and the wastegate control valve solenoid electrical connector. Use the General Equipment: Hose Clamp Remover/Installer
- Remove the wastegate control valve solenoid retainers and then remove the wastegate control valve solenoid.