Pinpoint Test C : P2535: Notes
WARNING: This page is about a different variant/trim than selected.
Refer to Starting System for schematic and connector information.
Normal Operation and Fault Conditions
When the ignition is turned to the START position the PCM receives a voltage signal on the crank detect circuit. When the required inputs have been received, the PCM supplies voltage and ground to the starter relay coil.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P2535 | Ignition Switch Run/Start Position Circuit High | This DTC is set when the PCM detects a short to voltage on the crank detect circuit while engine is running. |
Possible Sources
- Ignition switch
- PCM
- Wiring, terminals or connectors
Visual Inspection and Diagnostic Pre-checks
- Verify the CJB fuse 1 (15A).