PINPOINT TEST H : U3000:44, 45, 46, 48, 49 Or 4A: Notes
Normal Operation and Fault Conditions
Refer to Side And Rear Vision .
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| U3000:44 | Control Module: Data Memory Failure | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects an internal RAM memory failure. |
| U3000:45 | Control Module: Program Memory Failure | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects an internal software failure. |
| U3000:46 | Control Module: Calibration/Parameter Memory Failure | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects a failure with the EEPROM. |
| U3000:48 | Control Module: Supervision Software Failure | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects a calibration failure. |
| U3000:49 | Control Module: Internal Electronic Failure | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects an internal electronic communication failure. |
| U3000:4A | Control Module: Incorrect Component Installed | Sets in continuous memory and on-demand when the SOD-L or SOD-R detects a weak or no sample radar signal. |