The Ignition Key Can Be Turned To The Off Position When The Selector Lever Is Not In Park
Refer to Wiring Diagrams Cell 37 for schematic and connector information.
Normal Operation and Fault Conditions
The key removal inhibit solenoid (part of the ignition switch) receives battery voltage from BCM fuse 78 (5A). When the selector lever is moved out of the PARK position, the brake shift interlock actuator (part of the selector lever) closes, providing a ground circuit to the key removal inhibit solenoid. The key removal inhibit solenoid activates and prevents the ignition lock cylinder from being turned to the OFF position and the key from being removed.
Possible Causes
- Wiring, terminals or connectors
- Key removal inhibit solenoid (part of the ignition switch)
- Brake shift interlock actuator (part of the selector lever)