Pinpoint Test BT : U0159:00
- BT1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify there is an observable symptom present.
Is an observable symptom present?
Yes GO to BT2 No CLEAR the DTC. The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. - BT2 CHECK THE COMMUNICATION NETWORK
- Using a diagnostic scan tool, perform the network test.
Does the PAM pass the network test?
Yes GO to BT3 No REFER to: Communications Network . - BT3 PERFORM THE BCM (BODY CONTROL MODULE) SELF-TEST
- Using a diagnostic scan tool, perform the BCM self-test.
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Parking Aid . No GO to BT4 - BT4 CHECK THE GWM (GATEWAY MODULE A) DIAGNOSTIC TROUBLE CODES (DTCS)
- Using a diagnostic scan tool, check the GWM Continuous Memory Diagnostic Trouble Codes (DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Communications Network . No GO to BT5 - BT5 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Using a diagnostic scan tool, perform the IPC self-test.
Is DTC U3003:16 or DTC U3003:17 recorded?
Yes REFER to DTC Chart: IPC in this article. No GO to BT6 - BT6 RECHECK THE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during the PMI, or the PMI may not have been carried out.
- Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Repeat the IPC self-test.
Is DTC U0159:00 still present?
Yes GO to BT7 No The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. - BT7 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION
- Ignition OFF.
- Disconnect and inspect the BCM and all related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all the BCM and all related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to BCM Hardware Testing . CLEAR the Diagnostic Trouble Codes (DTCs). REPEAT the IPC self-test. If DTC U0184:00 is still present, GO to BT8 No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues. - BT8 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC and all related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC and all related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Hardware Testing . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.