LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2015 >> Transit Connect Titanium >> Repair and Diagnosis (Single Page) >> Electrical >> Gauges >> Instrumentation, Message Center And Warning Chimes >> Diagnosis And Testing >> Instrumentation, Message Center and Warning Chimes >> Pinpoint Tests >> Pinpoint Test AU : U0121:00 >> Pinpoint Test AU : U0121:00

Pinpoint Test AU : U0121:00

  1. AU1 VERIFY THE CUSTOMER CONCERN

    • Ignition ON.
    • Verify there is an observable symptom present.

    Is an observable symptom present? 

    Yes  GO to  AU2
    No  The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
  2. AU2 CHECK THE COMMUNICATION NETWORK

    • Using a diagnostic scan tool, perform a network test.

    Does the ABS module pass the network test? 

    Yes  GO to  AU3
    No  REFER to: Communications Network
  3. AU3 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE BCM (BODY CONTROL MODULE) SELF-TEST

    • Using a diagnostic scan tool, perform the BCM self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Body Control Module (BCM)
    No  GO to  AU4
  4. AU4 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE ABS (ANTI-LOCK BRAKE SYSTEM) MODULE SELF-TEST

    • Using a diagnostic scan tool, perform the ABS module self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Anti-Lock Brake System (ABS) and Stability Control
    No  GO to  AU5
  5. AU5 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST

    • Using a diagnostic scan tool, perform the IPC self-test.

    Is DTC U3006:16 or DTC U3006:17 recorded? 

    Yes  REFER to DTC Chart: IPC 
    No  GO to  AU6
  6. AU6 RECHECK THE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)

    NOTE: If new modules were installed prior to the DTC being set, the module configuration can be incorrectly set during the PMI or the PMI may not have been carried out.

    • Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
    • Wait 10 seconds.
    • Using a diagnostic scan tool, perform the IPC self-test.

    Is DTC U0121:00 still present? 

    Yes  GO to  AU7
    No  The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
  7. AU7 CHECK FOR DTC (DIAGNOSTIC TROUBLE CODE) U0121:00 SET IN OTHER MODULES

    • Using a diagnostic scan tool, clear all Diagnostic Trouble Codes (DTCs).
    • Ignition OFF.
    • Ignition ON.
    • Wait 10 seconds.
    • Using a diagnostic scan tool, perform the continuous memory self-test.
    • Retrieve the Continuous Memory Diagnostic Trouble Codes (CMDTCs) from all modules.

    Is DTC U0121:00 set in other modules on the network? 

    Yes  GO to  AU8
    No  GO to  AU9
  8. AU8 CHECK FOR CORRECT ABS (ANTI-LOCK BRAKE SYSTEM) MODULE OPERATION

    • Ignition OFF.
    • Disconnect and inspect all ABS module connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the ABS module connectors. Make sure they seat and latch correctly.
    • Operate the system and verify the concern is still present

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new ABS module (part of the HCU). REFER to: Hydraulic Control Unit (HCU)
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.
  9. AU9 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION

    • Ignition OFF.
    • Disconnect and inspect the IPC connector.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the IPC connector. Make sure it seats and latches correctly.
    • Operate the system and verify the concern is still present

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Hardware Testing .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.