Removal And Installation: Thermostat: Removal
NOTE:
Removal steps in this procedure may contain installation details.
- 1.
Drain the cooling system. Refer to: Cooling System Draining and Vacuum Filling .
- 2.
Remove the air cleaner outlet pipe. Refer to: AIR CLEANER OUTLET PIPE - 5.0L 32V Ti-VCT/5.0L Ti-VCT V8 (308kW/418PS).
- 3.
Completely cover the accessory drive belts with waterproof plastic.
NOTE:
Cover the accessory drive belts to prevent coolant contamination of the belts.
- 4.
Remove the bolts and detach the coolant inlet connector.Torque
: 89 lb.in (10 Nm)
NOTE:
During installation, make sure the coolant outlet connection is fully seated on the thermostat housing before tightening the bolts.