B00D5:12 and B00D5:14: Notes
Refer to SUPPLEMENTAL RESTRAINT SYSTEM for schematic and connector information.
Normal Operation and Fault Conditions
The RCM briefly activates the PAD indicator to prove-out and verify to the occupants correct functional operation of the PAD indicator.
The RCM continuously monitors the PAD indicator circuits for the following faults:
- Open circuit.
- Short to voltage.
- Short to ground.
- Faulted PAD indicator.
If a fault is detected, the RCM stores DTC B00D5:12 or B00D5:14 in memory and sends a message to the IPC to illuminate the airbag warning indicator.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B00D5:12 | Restraint System Passenger Disable Indicator: Circuit Short to Battery | A fault is indicated when the RCM senses a short to voltage on the PAD indicator circuit for more than 4 seconds. |
| B00D5:14 | Restraint System Passenger Disable Indicator: Circuit Short to Ground or Open | A fault is indicated when the RCM senses a short to ground or an open circuit on the PAD indicator circuit for more than 4 seconds. An open ignition circuit to the PAD indicator also sets this DTC. |
Possible Sources
- Wiring, terminals or connectors
- PAD indicator
- RCM
Visual Inspection and Diagnostic Pre-checks
- Verify BCM fuse 19 (5A) is OK.