Home >> Ford >> 2014 >> Mustang Base, 2D Convertible, Automatic Trans >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Cluster Illumination And Panel Illumination >> Diagnosis And Testing >> Instrument Cluster and Panel Illumination >> Pinpoint Tests >> Pinpoint Test D: All Dimmable Switch Illumination Is Always On >> Pinpoint Test D: All DIMMABLE Switch Illumination Is Always On

Pinpoint Test D: All DIMMABLE Switch Illumination Is Always On

NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  1. D1 CHECK THE EXTERIOR LIGHTING 
    • Ignition OFF.
    • Ensure the headlamp switch is OFF.
    • Observe the exterior lighting components.

    Are any exterior lighting components illuminated? 

  2. D2 CHECK THE SJB BACKLIGHTING OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE 
    • Disconnect: SJB C2280B  .
    • Ignition ON.

    Do the dimmable backlighted components continue to illuminate? 

    • Yes  : REPAIR circuit VLN04 (VT/GY) for a short to voltage. CLEAR the DTCs. REPEAT the self-test.
    • No  : GO to D3  .
  3. D3 CHECK FOR CORRECT SJB OPERATION 
    • Disconnect all the SJB connectors.
    • Check for:
      • corrosion
      • damaged pins
      • pushed-out pins
    • Connect all the SJB connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.

    Is the concern still present? 

    • Yes  : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.