Home >> Ford >> 2014 >> Fusion Titanium Hybrid >> Repair and Diagnosis >> External Pages >> Different car >> Section 421 (Information Center - Instrumentation, Message Center And Warning Chimes (Except Hybrid/ENERGI)) >> Diagnosis And Testing >> Instrumentation, Message Center and Warning Chimes >> Pinpoint Tests >> Pinpoint Test BR : U0159:00 >> Pinpoint Test BR : U0159:00

Pinpoint Test BR : U0159:00

WARNING: This page is about a different car, the 2015 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.

  1. BR1 VERIFY THE CUSTOMER CONCERN

    • Ignition ON.
    • Verify there is an observable symptom present.

    Is an observable symptom present? 

    Yes  GO to  BR2
    No  The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
  2. BR2 CHECK THE COMMUNICATION NETWORK

    • Using a diagnostic scan tool, perform the network test.

    Does the Parking Aid Module (PAM) pass the network test? 

    Yes  GO to  BR3
    No  REFER to: Communications Network
  3. BR3 PERFORM THE BCM (BODY CONTROL MODULE) SELF-TEST

    • Using a diagnostic scan tool, perform the BCM self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Parking Aid REFER to: Parking Aid
    No  GO to  BR5
  4. BR4 CHECK THE GWM (GATEWAY MODULE A) DIAGNOSTIC TROUBLE CODES (DTCS)

    • Using a diagnostic scan tool, check the GWM Continuous Memory Diagnostic Trouble Codes (DTCs).

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Communications Network
    No  GO to  BR5
  5. BR5 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST

    • Using a diagnostic scan tool, perform the IPC self-test.

    Is DTC U3006:16 or DTC U3006:17 recorded? 

    Yes  REFER to DTC Chart: Instrument Panel Cluster (IPC) 
    No  GO to  BR6
  6. BR6 RECHECK THE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)

    NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during the Programmable Module Installation (PMI), or the Programmable Module Installation (PMI) may not have been carried out.

    • Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
    • Wait 10 seconds.
    • Repeat the IPC self-test.

    Is DTC U0159:00 still present? 

    Yes  GO to  BR7
    No  The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
  7. BR7 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION

    • Ignition OFF.
    • Disconnect and inspect all BCM connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect all the BCM connectors. Make sure they seat and latch correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to BCM Hardware Testing (Except Hybrid/Energi) . CLEAR the Diagnostic Trouble Codes (DTCs). REPEAT the IPC self-test. If DTC U0184:00 is still present, GO to  BR8
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.
  8. BR8 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION

    • Ignition OFF.
    • Disconnect and inspect IPC connector.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the IPC connector. Make sure it seats and latches correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Hardware Testing .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.