LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2014 >> Flex SEL, FWD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> Sunroof - Roof Opening Panel >> Diagnosis And Testing >> Roof Opening Panel >> Pinpoint Tests >> Pinpoint Test F: The Roof Opening Panel Does Not Open or Close in VENT Position >> Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In Vent Position

Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In Vent Position

  1. F1 CHECK THE MOTOR/MODULE FOR INITIALIZATION 

    Was the roof opening panel initialization procedure successful? 

    • Yes  : The system is operating normally at this time. The roof opening panel motor was not initialized.
    • No  : GO to F2  .
  2. F2 CHECK THE ROOF OPENING PANEL SWITCH 

    Is the roof opening panel switch OK? 

    • Yes  : GO to F3  .
    • No  : INSTALL a new roof opening panel switch. TEST the system for normal operation.
  3. F3 CHECK CIRCUIT CPR38 (WH/BU) FOR AN OPEN 
    • Measure the resistance between overhead console C912-3  , circuit CPR38 (WH/BU), and roof opening panel motor/module C921-4  , circuit CPR38 (WH/BU) harness side.
      Fig 1: Measuring Resistance Between Overhead Console C912-3 And Roof Opening Panel Motor/Module C921-4, Circuit CPR38
      G06071264Courtesy of FORD MOTOR CO.

    Is the resistance less than 5 ohms? 

    • Yes  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR38 (WH/BU) between the roof opening panel switch socket and overhead console C912-3  . If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to F4  .
    • No  : REPAIR the circuit. TEST the system for normal operation.
  4. F4 CHECK CIRCUIT CPR40 (YE/OG) FOR AN OPEN 
    • Measure the resistance between overhead console C912-8  , circuit CPR40 (YE/OG), and roof opening panel motor/module C921-10  , circuit CPR40 (YE/OG) harness side.
      Fig 2: Measuring Resistance Between Overhead Console C912-8 And Roof Opening Panel Motor/Module C921-10, Circuit CPR40
      G06071262Courtesy of FORD MOTOR CO.

    Is the resistance less than 5 ohms? 

    • Yes  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR40 (YE/OG) between the roof opening panel switch socket and overhead console C912-8  . If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to F5  .
    • No  : REPAIR the circuit. TEST the system for normal operation.
  5. F5 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION 
    • Disconnect all roof opening panel motor/module connectors.
    • Check for:
      • corrosion.
      • bent pins.
      • pushed-out pins.
    • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.

    Is the concern still present? 

    • Yes  : INSTALL a new roof opening panel motor/module. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.