Pinpoint Test A: The IPC (Instrument Panel Cluster) Is Inoperative
- A1 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Ignition ON.
- Using a diagnostic scan tool, perform the IPC self-test.
Is DTC U3010:01 recorded?
- Yes : REFER to: STEERING WHEEL AND COLUMN ELECTRICAL COMPONENTS .
- No : GO to A2
- A2 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) B+ VOLTAGE SUPPLY
- Ignition OFF.
- Disconnect IPC C220A .
- Measure:
Positive Lead Measurement/Action Negative Lead C220A-32 Ground
Is the voltage greater than 11 volts?
- Yes : GO to A3
- No : VERIFY the CJB fuse 3 (7.5A) is OK. If OK, REPAIR the circuit for an open. If not OK, REFER to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short. TEST the system for normal operation.
- A3 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) RUN VOLTAGE SUPPLY
Is the voltage greater than 11 volts?
- Yes : GO to A4
- No : VERIFY the CJB fuse 21 (7.5A) is OK. If OK, REPAIR the circuit for an open. If not OK, REFER to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short. TEST the system for normal operation.
- A4 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) ACC VOLTAGE SUPPLY
Is the voltage greater than 11 volts?
- Yes : GO to A5
- No : VERIFY the CJB fuse 19 (7.5A) is OK. If OK, REPAIR the circuit for an open. If not OK, REFER to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short. TEST the system for normal operation.
- A5 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) GROUND CIRCUIT FOR AN OPEN
Is the voltage greater than 11 volts?
- Yes : GO to A6
- No : REPAIR the circuit.
- A6 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes
: CHECK OASIS
for any applicable Technical Service Bulletins (TSBs). If a TSB
exists for this concern, DISCONTINUE this test and FOLLOW TSB
instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new IPC
.
REFER to: INSTRUMENT PANEL CLUSTER (IPC) .
- No : The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.