LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2013 >> Fusion Titanium, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Steering Column Switches >> Steering Column Electrical Components (Except Hybrid) >> Diagnosis and Testing >> Steering Wheel and Column Electrical Components >> Pinpoint Tests >> PINPOINT TEST B: No Power in ACC - Conventional Ignition Switch >> No Power In Acc - Conventional Ignition Switch

No Power In Acc - Conventional Ignition Switch

  1. B1 CHECK FOR ACC VOLTAGE AT THE BCM (BODY CONTROL MODULE) 
    • Ignition OFF.
    • Disconnect BCM C2280G  .
    • Accessory ON.
    • Measure:
      Positive Lead Measurement/Action Negative Lead
      C2280G-50  VOLTAGE Ground

    Is the voltage greater than 11 volts? 

    1. Yes  : GO to  B3
    2. No  : GO to B2 
  2. B2 CHECK THE IGNITION ACC CIRCUIT FOR AN OPEN 
    • Ignition OFF.
    • Disconnect Ignition Switch C250  .
    • Measure:
      Positive Lead Measurement/Action Negative Lead
      C2280G-50  OHM C250-6 

    Is the resistance less than 3 ohms? 

    1. Yes  : INSTALL a new ignition switch.

      REFER to: IGNITION SWITCH  .

    2. No  : REPAIR the circuit.
  3. B3 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION 
    • Disconnect and inspect all BCM  connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the BCM  connectors. Make sure they seat and latch correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    1. Yes  : CHECK OASIS  for any applicable Technical Service Bulletins (TSBs). If a TSB  exists for this concern, DISCONTINUE this test and FOLLOW TSB  instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new BCM  . REFER to: BODY CONTROL MODULE (BCM) .
    2. No  : The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.