Component testing procedure
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Horizontal circuit | 11 and 16 17 and 10 |
Forward | Closed circuit |
| Closed circuit | |||
| 11 and 17 16 and 10 |
Rearward | Closed circuit | |
| Closed circuit | |||
| Front Height circuit | 11 and 15 14 and 10 |
Up | Closed circuit |
| Closed circuit | |||
| 11 and 14 15 and 10 |
Down | Closed circuit | |
| Closed circuit | |||
| Rear Height circuit | 11 and 18 19 and 10 |
Up | Closed circuit |
| Closed circuit | |||
| 11 and 19 16 and 10 |
Down | Closed circuit | |
| Closed circuit | |||
| Recline circuit | 11 and 3 1 and 10 |
Incline | Closed circuit |
| Closed circuit | |||
| 11 and 1 3 and 10 |
Recline | Closed circuit | |
| Closed circuit | |||
| Lumbar circuit | 11 and 2 20 and 10 |
Inflate | Closed circuit |
| Closed circuit | |||
| 11 and 20 2 and 10 |
Deflate | Closed circuit | |
| Closed circuit |