Pinpoint Test D: The Roof Opening Panel Is Noisy During Operation
- D1 CHECK THE ROOF OPENING PANEL FOR OBSTRUCTIONS OR DAMAGE
- Check the roof opening panel for any obstructions and damage.
- Are there any obstructions and/or damage?
- Yes
: REMOVE all obstructions. REPAIR any damage. If the damage cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel . TEST the system for normal operation.
- No
: GO to D2.
- D2 CHECK THE ROOF OPENING PANEL OPERATION
- Check the roof opening panel during operation.
- Is the roof opening panel glass loose or incorrectly aligned?
- D3 CHECK THE ROOF OPENING PANEL TRACKS
- Open the roof.
- Check the roof opening panel tracks for obstructions and damage.
- Are the roof opening panel tracks OK?
- Yes
: GO to D4.
- No
: REMOVE all obstructions and REPAIR any damage. If the roof opening panel tracks cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel . TEST the system for normal operation.
- D4 CHECK THE ROOF OPENING PANEL SHIELD
- Check the roof opening panel shield for correct movement.
- Is the roof opening panel shield moving correctly?
- Yes
: GO to D5.
- No
: REMOVE and REINSTALL the roof opening panel shield. If necessary, INSTALL a new roof opening panel shield. REFER to Roof Opening Panel Shield . TEST the system for normal operation.
- D5 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES
- Check the roof opening panel lifter assemblies for obstructions and damage.
- Are the roof opening panel lifter assemblies OK?
- Yes
: GO to D6.
- No
: REMOVE all obstructions and REPAIR any damage. If the roof opening panel lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel . TEST the system for normal operation.
- D6 CHECK THE ROOF OPENING PANEL MODULE
- Remove the roof opening panel module and leave the electrical connector connected.
- Operate the roof opening panel to the fully OPEN and CLOSED position.
- Does the module make excessive noise?
- Yes
: INSTALL a new roof opening panel module. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- No
: REINSTALL the roof opening panel module. TEST the system for normal operation. If the roof opening panel is still noisy, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel . If the roof opening panel is no longer noisy, the system is operating correctly. The concern may have been caused by an incorrectly installed roof opening panel motor.