Normal Operation and Fault Conditions
The start/stop switch illumination is ground side controlled by the BCM.
DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1249:12 | Start Button Illumination: Circuit Short to Battery | Sets in continuous memory and on-demand when the BCM detects battery voltage on the start button illumination ground circuit. |
| B1249:14 | Start Button Illumination: Circuit Short to Ground or Open | Sets in continuous memory when the BCM detects a short to ground or open on the start button illumination ground circuit. |
| U1000:00 | Solid State Driver Protection Active - Driver Disabled: No Sub Type Information | Sets in continuous memory when the BCM has temporarily disabled an output driver because an excessive current draw exists. The BCM cannot enable the output until the cause of the excessive current draw is corrected, the BCM DTCs have been cleared and a successful BCM self-test is run. |
| U3000:49 | Control Module: Internal Electronic Failure | Sets in continuous memory when the BCM has permanently disabled an output driver because an excessive current draw has occurred more times than the BCM output driver can withstand. ADDRESS all other BCM DTCs. The cause of the excessive current draw must be corrected before a new BCM is installed. |