LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2013 >> Edge SEL, 2.0L Eng VIN 9 >> Repair and Diagnosis >> External Pages >> Different car >> Section 289 (Sunroof - Roof Opening Panel) >> Diagnosis And Testing >> Roof Opening Panel >> Pinpoint Tests >> Pinpoint Test F: The Roof Opening Panel Does Not Open or Close in the VENT Position >> Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In The Vent Position

Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In The Vent Position

WARNING: This page is about a different car, the 2014 Lincoln MKX and 2014 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  1. F1 CHECK THE ROOF OPENING PANEL MOTOR FOR INITIALIZATION 

    Is the concern still present? 

    • Yes  : GO to  F2.
    • No  : The system is operating normally at this time. The roof opening panel motor was not initialized.
  2. F2 CHECK THE ROOF OPENING PANEL SWITCH 
    • Ignition OFF.
    • Disconnect: Roof Opening Panel Switch C9001.
    • Carry out the roof opening panel switch component test.

      Refer to OEM WIRING DIAGRAMS COMPONENT TESTING for component testing.

    Did the roof opening panel switch pass the component test? 

  3. F3 CHECK THE ROOF OPENING PANEL CONTROL CIRCUIT FOR AN OPEN 
    • Disconnect: Roof Opening Panel Motor Assembly C920.
    • Measure the resistance between roof opening panel switch C9001-6  , circuit CPR38 (WH/BU), harness side and roof opening panel motor assembly C920-6  , circuit CPR38 (WH/BU) harness side.
      Fig 1: Measuring Resistance Between Roof Opening Panel Switch C9001-6, Circuit CPR38 (WH/BU) And Roof Opening Panel Motor Assembly C920-6
      G06286064Courtesy of FORD MOTOR CO.

    Is the resistance less than 5 ohms? 

    • Yes  : GO to  F4.
    • No  : REPAIR the circuit. TEST the system for normal operation.
  4. F4 CHECK THE ROOF OPENING PANEL MOTOR WIRING HARNESS 
    • Check the roof opening panel motor wiring harness for loose pins, an open or a short between roof opening panel motor assembly C920-6  , circuit CPR38, component side and the roof opening panel sliding glass motor harness connector.

    Is the roof opening panel motor wiring harness OK? 

  5. F5 CHECK THE ROOF OPENING SLIDING GLASS PANEL MOTOR FOR CORRECT OPERATION 
    • Disconnect all roof opening panel motor connectors.
    • Check for:
      • corrosion.
      • bent or pushed-out pins.
    • Connect all roof opening panel motor connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.

    Is the concern still present?