Pinpoint Test D: A Single Power Window Is Inoperative - RH Front
WARNING: This page is about a different car, the 2012 Ford Pickup, 2012 Ford F550 Super Duty, 2012 Ford F450 Super Duty, and 2012 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- D1 CHECK THE VOLTAGE TO THE RH FRONT WINDOW CONTROL SWITCH
- Disconnect: RH Front Window Control Switch C604.
- Ignition ON.
- Measure the voltage between RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side and ground.
- Is the voltage greater than 10 volts?
NOTE: For Crew Cab, set the window lock switch to the UNLOCK position.Fig 1: Measuring Voltage Between RH Front Window Control Switch C604-3, Circuit CPW14 (VT/WH), Harness Side And GroundCourtesy of FORD MOTOR CO.
- Yes : GO to D3.
- No
: For regular and SuperCab, REPAIR circuit CBP01 (BU)/CPW14 (VT/WH). TEST the system for normal operation.
For Crew Cab, GO to D2.
- D2 CHECK THE RH FRONT WINDOW CONTROL SWITCH POWER CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: LH Front Window Control Switch C504B.
- Measure the resistance between LH front window control switch C504B-2, circuit CPW14 (VT/WH), harness side and RH front window control switch C604-3, circuit CPW14 (VT/WH), harness side.
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- No : REPAIR the circuit(s). TEST the system for normal operation.
- D3 CHECK THE LH FRONT WINDOW CONTROL SWITCH NORMALLY CLOSED SWITCH CONTACTS
- Ignition OFF.
- Measure the resistance between RH front window control switch C604-1 circuit CPW12 (GN/OG), harness side and ground; and between RH front window control switch C604-6, circuit CPW13 (BN/YE), harness side and ground.
- Are the resistances less than 5 ohms?
- Yes : GO to D5.
- No : GO to D4.
- D4 CHECK FOR AN OPEN CIRCUIT BETWEEN THE LH FRONT WINDOW CONTROL SWITCH AND THE RH FRONT WINDOW CONTROL SWITCH
- Disconnect: LH Front Window Control Switch C504A (Crew Cab) or C535 (regular and SuperCab).
- Measure the resistance between LH front window control switch C504A-3(Crew Cab) or C535-3(regular and SuperCab), circuit CPW12 (GN/OG), harness side and RH front window control switch C604-1, circuit CPW12 (GN/OG), harness side.
- Measure the resistance between LH front window control switch C504A-8(Crew Cab) or C535-8(regular and SuperCab), circuit CPW13 (BN/YE), harness side and RH front window control switch C604-6, circuit CPW13 (BN/YE), harness side.
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- No : REPAIR the circuit(s). TEST the system for normal operation.
- D5 CHECK THE RH FRONT WINDOW CONTROL SWITCH
- Ignition ON.
- Connect a fused jumper wire between RH front window control switch C604-1, circuit CPW12 (GN/OG) and RH front window control switch C601-5, circuit CPW20 (WH/OG); and a second jumper wire between RH front window control switch C604-3, circuit CPW14 (VT/WH) and RH front window control switch C604-2, circuit CPW19 (VT), harness side. The RH front window should move in the downward direction.
- Connect a fused jumper wire between RH front window control switch C604-6, circuit CPW13 (BN/YE) and RH front window control switch C604-2, circuit CPW19 (VT); and a second jumper wire between RH front window control switch C604-3, circuit CPW14 (VT/WH) and RH front window control switch C604-5, circuit CPW20 (WH/OG), harness side. The RH front window should move in the upward direction.
- Does the window operate correctly?
- Yes : If the RH front window did not operate with the RH front window controls, INSTALL a new RH front window regulator control switch. If the RH front power window did operate with the RH front window control switch but not with the LH front window control switch, INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- No : GO to D6.
- D6 CHECK THE RH FRONT WINDOW MOTOR CIRCUITS FOR AN OPEN
- Ignition OFF.
- Disconnect: RH Front Window Motor C608.
- Measure the resistance between RH front window control switch C604-5, circuit CPW20 (WH/OG), harness side and RH front window motor C608-1, circuit CPW20 (WH/OG), harness side.
- Measure the resistance between RH window control switch C604-2, circuit CPW19 (VT), harness side and RH window motor C608-2, circuit CPW19 (VT), harness side.
- Are the resistances less than 5 ohms?
- Yes : INSTALL a new RH front window regulator and motor. REFER to WINDOW REGULATOR AND MOTOR - FRONT DOOR . TEST the system for normal operation.
- No : REPAIR the circuit(s). TEST the system for normal operation.