Principles of Operation: Notes
NOTE:
The Smart Junction Box (SJB) is also known as the Generic Electronic Module (GEM).
NOTE:
When installing a new Instrument Panel Cluster (IPC), it is necessary to upload the module configuration to the scan tool. Following installation of the IPC, download the module configuration from the scan tool to the IPC. Refer to
MODULE CONFIGURATION
to carry out the Programmable Module Installation (PMI). On vehicles equipped without Intelligent Access (IA), it is also necessary to carry out a parameter reset procedure whenever a new IPC or PCM is installed. Refer to
ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS)
.