Pinpoint Test B : TFT (Transmission Fluid Temperature) Sensor
WARNING: This page is about a different car, the 2015 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
- B1 CHECK TFT INPUT SIGNAL
- Ignition OFF.
- Disconnect: Transmission Vehicle Harness C1575 .
- Inspect the connector for damaged or pushed out terminals, corrosion, loose wires and missing or damaged seals.
- Connect the diagnostic tool.
- Ignition ON.
- Enter the following mode on the diagnostic scan tool: TFT PIDs TFT and TFTV.
Does the TFT PID display -58°C (-72°F) and the TFTV PID display 4.96 to 5.10 volts?
Yes GO to B2 No REPAIR the circuit. - B2 CHECK TFT SIGNAL INPUT CIRCUIT FOR VOLTAGE
- Measure:
Positive Lead Measurement / Action Negative Lead C1575-6 Ground
Is the voltage between 4.8 and 5.1 volts?
Yes GO to B3 No INSPECT and REPAIR the open circuit. If an open circuit is not found, INSTALL a new PCM, REFER to: POWERTRAIN CONTROL MODULE (PCM) . PROGRAM the PCM with the latest calibration level. PERFORM the Solenoid Body Strategy Data Download procedure. Refer to: Transmission Strategy Download . - Measure:
- B3 CHECK TFT SIGNAL RETURN CIRCUIT
Does the TFT PID display 190°-195°C (374°-383°F) and the TFTV PID display 0 volts?
Yes GO to B4 No INSPECT and REPAIR the transmission vehicle harness signal return circuit for an open. If an open circuit is not found, INSTALL a new PCM, REFER to: POWERTRAIN CONTROL MODULE (PCM) . PROGRAM the PCM with the latest calibration level. PERFORM the Solenoid Body Strategy Data Download procedure. Refer to: Transmission Strategy Download . - B4 CHECK TFT SENSOR RESISTANCE
- Measure the resistance between the transmission C1575-5
and C1575-6
, component side using the following chart:
Positive Lead Measurement / Action Negative Lead Component side, pin 5 Component side, pin 6 C1575-5 C1575-6 °C °F Resistance -40 to -20 -40 to -4 967K-284K -19 to -1 -3 to 31 284K-100K 0-20 32-68 100K-37K 21-40 69-104 37K-16K 41-70 105-158 16K-5K 71-90 159-194 5K-2.7K 91-110 195-230 2.7K-1.5K 111-130 231-266 1.5K-0.8K 131-150 267-302 0.8K-0.54K
Does the temperature to resistance specification match?
Yes To diagnose an overheating concern REFER to: Diagnosis By Symptom . No INSPECT and CLEAN the TFT sensor on the molded leadframe for metallic contamination. INSTALL a new molded leadframe if no debris was found, REFER to: Transmission Strategy Download . CLEAR the DTCs. - Measure the resistance between the transmission C1575-5
and C1575-6
, component side using the following chart: