Typical Diagnostic Reference Values

WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2015 Lincoln Navigator, 2015 Lincoln MKZ, 2015 Lincoln MKX, 2015 Lincoln MKT, and 2015 Lincoln MKS. However, it is still accessible from the selected car via links, so may be relevant.
Sensors/Inputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
BOO1 B13 OFF OFF OFF OFF ON/OFF
AAT B17 -3 (26.60) -3 (26.60) -1 (30.20) -3 (26.60) DEG C (DEG F)
AAT_V B17 4.08 4.08 4.07 4.08 VOLTS
APP1 B28 0.78 0.78 0.95 1.71 VOLTS
APP2 B29 0.39 0.39 0.48 0.86 VOLTS
FPM B32 100 39.99 39.98 39.99 %
MAF B40 0 2.83 13.48 12.22 g/s
MAF_HZ B40 727.25Hz 1.96 3.69 3.69 kHz
KEYST B42 ON ON ON ON ON/OFF
BOO2 B46 OFF OFF OFF OFF ON/OFF
IAT B47 2.93/25 (77) 3/24 (75.20) 4.02/2 (35.60) 4.09/1 (33.80) VOLTS/DEG C (DEG F)
B+ B62 12.82 14.22 14.29 14.22 VOLTS
FTP B65 2.63/29 (0) 2.61/-14 (0) 2.24/-667 (-0.10) 2.28/-598 (-0.09) VOLTS/Pa (PSI)
FTP_H2O B65 0.10 -0.07 -2.69 -2.42 in-H2 0
O2S11_CUR E27 (I) switching switching switching mA/uA
CHT E39 3.55/95 (203) 3.69/91 (195.80) 3.66/92 (197.60) 3.63/93 (199.40) VOLTS/DEG C (DEG F)
MAP E40 99 (14.36) 32 (4.64) 54 (7.83) 46 (6.67) kPa (PSI)
MAP_GAUGE E40 2 (0.29) 69 (10) 60 (8.70) 55 (7.98) kPa (PSI)
MAP_V E40 4.03 1.31 2.20 1.87 VOLTS
TP1 E41 4.10/17.64 4.32/13.33 4.07/18.43 3.40/31.76 VOLTS/%
KNOCK_1 E43 273 268 864 351 COUNT
TP2 E58 1.22/24.31 0.78/15.29 1.05/20.78 1.08/21.56 VOLTS/%
HTRCM11 E69 0 2.55 2.55 2.55 A
O2S12 T29 (I) switching (D) switching (D) switching (D) VOLTS
HTRCM12 T49 0 679 709 709 mA
AC_REQ PID NO NO NO NO YES/NO
APP PID 0 0 0.95 29.50 %
APP_MAXDIFF PID 0 0 -0.06 -0.06 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
APP1 (APP_D) PID 15.29 15.29 19.21 34.11 %
APP2 (APP_E) PID 7.45 7.84 9.80 17.25 %
BARO PID 90 (13.05)/156.11 90 (13.05)/156.11 90 (13.05)/156.11 90 (13.05)/156.11 kPa (PSI)/Hz
BRKOVR_ACTION PID 4 4 4 4 NUMERIC VALUE
BRKOVRD_POSS PID 49 49 50 50 NUMERIC VALUE
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 13.49 (8.38) 13.49 (8.38) 13.49 (8.38) 15.49 (9.63) KM (MILES)
EGR_STEP PID 0 0 24 0 POSITION
EQ_RAT11 PID 0/0:1 1.04/14.67:1 0.99/14.52:1 1.02/14.89:1 RATIO
ETC_ACT PID 7.73 2.15 8.81 21.70 DEG
ETC_TRIM PID 0 0 0 0 DEG
FLI PID 34.11 (H) 34.11 (H) 27.45 (H) 29.02 (H) %
INJPWR_M PID 3.17 14.30 14.30 14.28 VOLTS
LOAD PID 0.00 (I) 25.09 41.17 34.51 %
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 0 0 COUNT
O2S11_IMPED PID 5 0.09 0.09 0.09 VOLTS
O2S11_READY PID NO YES YES YES YES/NO
O2S11_TR PID 0 0 0 0 Kohm
OCTADJ_R_LRND PID 15.88 15.88 22.40 22.40 %
RPM PID 0 700.25 1478 1721 RPM
SYNC PID NO YES YES YES YES/NO
TPMODE PID CT CT PT PT CLOSED/PART/WIDE OPEN THROTTLE
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Actuators/Outputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FP B19 75/OFF 39.21/ON 39.20/ON 39.28/ON %/ON/OFF
EVAPCV B20 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EGRMC1F E14 NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC2F E15 NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC3F E16 NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EGRMC4F E17 NO FAULT NO FAULT NO FAULT NO FAULT FAULT/NO FAULT
EVAPCP E32 0 10.05 95.86 43.25 %
VCTDC E67 0 0 0 0 %
HTR11 E69 OFF ON ON ON VOLTS/ON/OFF
O2S11_HTR E69 20 30.19 27.05 22.35 %
HTR12 T49 OFF ON ON ON VOLTS/ON/OFF
CYL_1-4_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
EGRPCT PID 0 0 45.88 0 %
ETC [TAC_PCT] PID 9.41 2.35 10.58 26.27 %
EVAP020C PID NO NO NO NO YES/NO
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FANDC PID 7.84 7.84 7.84 7.84 %
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
INJ1-4_OFF PID -- -- -- -- --/DISABLE
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MIL PID OFF OFF OFF OFF ON/OFF
O2_DS_DISBL PID YES YES NO NO YES/NO
RO2FT1 PID 0 1.03 1.50 -0.67 %
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 29.75 10.50 46.50 24.75 DEG
TQ_CNTRL PID ANTI THEFT IDLE SPEED CONTROL NONE REQUESTED CRUISE CONTROL STATUS
VCTADV PID 0 -0.12 0.12 0.18 DEG
VCTADVERR PID 0 0.31 -0.31 0 DEG
Other PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VREF B66/B52/E35 5 5 5 5 VOLTS
VPWR B67/B68 VBAT VBAT VBAT VBAT VOLTS