LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 616 (Engine Controls - Reference Values (Except Diesel & Hybrid)) >> 2.0L GTDI Edge >> Typical Diagnostic Reference Values

Typical Diagnostic Reference Values

WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2015 Lincoln Navigator, 2015 Lincoln MKZ, 2015 Lincoln MKX, 2015 Lincoln MKT, and 2015 Lincoln MKS. However, it is still accessible from the selected car via links, so may be relevant.
Sensors/Inputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
CAC_T B32         DEG C (DEG F)
CAC_V B32         VOLTS
FP B39         %/ON/OFF
AAT B51         DEG C (DEG F)
AAT_V B51         VOLTS
APP2 B54         VOLTS
APP1 B55         VOLTS
O2S12 B56         VOLTS
BOO2 B65         ON/OFF
BOO1 B66         ON/OFF
FLP B71         kPa (PSI)
FLP_V B71         VOLTS
FTP B73         VOLTS/kPa (PSI)
FTP_H2O B73         in-H 20
TCBP B74         kPa (PSI)
TCBP_V B74         VOLTS
IAT B75         VOLTS/DEG C (DEG F)
MAP E33         VOLTS/kPa (PSI)
MAP_GAUGE E33         in-H2 O
ECT E36         DEG C (DEG F)
FRP E37         VOLTS/kPa (PSI)
CHT2 E46         DEG C (DEG F)
KNOCK_2 E50         N/A
TP2 E52         VOLTS/%
O2S11_CUR E63         uA
KNOCK_1 E65         N/A
TP1 E68         VOLTS/%
AC_REQ PID         YES/NO
APP PID         %
APP_MAXDIFF PID         DEG
APP_MODE PID         NO PEDAL/PART PEDAL
APP1 (APP_D) PID         %
APP2 (APP_E) PID         %
B+ PID         VOLTS
BARO PID         VOLTS/kPa (PSI)/Hz/in-H2 O
BRKOVR_ACTION PID         NUMERIC VALUE
BRKOVRD_POSS PID         NUMERIC VALUE
DECHOKE PID         YES/NO
DIST_BRKOVRD PID         KM (MILES)
EQ_RAT11 PID         RATIO
ETC_ACT PID         DEG
ETC_TRIM PID         DEG
LOAD PID         %
MISFIRE PID         YES/NO
MP_LRN PID         YES/NO
NUM_MISFIRE PID         COUNT
O2S11_IMPED PID         VOLTS
O2S11_READY PID         YES/NO
O2S11_TR PID         Kohm
OCTADJ_R_LRND PID         %
RPM PID         RPM
SYNC PID         YES/NO
TP1_LRN_TRIM PID         DEG
TP2_LRN_TRIM PID         DEG
TPMODE PID         CLOSED/PART/WIDE OPEN THROTTLE
TURBO_BP1_STAT PID         FAULT/NO FAULT
VCT_EXH_ACT1 PID         DEG
VCT_EXH_DIF1 PID         DEG
VCT_INT_ACT1 PID         DEG
VCT_INT_DIF1 PID         DEG
VCTSYS PID         OPEN LOOP/CLOSED LOOP
VSS PID         km/h/MPH
Actuators/Outputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
HTR12 B1         ON/OFF
HTRCM12 B1         mA
EVAPCV B20         %/ON-OFF
EVAPCP B22         %
FPM B27         %
VCT_INT_DC1 E1         %
TURBO_BPASS E3         ON/OFF
HTR11 E14         ON/OFF
O2S11_HTR E14         %
TURBO_WGATE E16         %
VCT_EXH_DC1 E29         %
ETC [TAC_PCT] PID         %
EVAP020C PID         YES/NO
EVAPSOAK PID         YES/NO
EVAPSTA PID         STATUS
FUELSYS PID         OPEN/CLOSED LOOP
LONGFT1 PID         %
MIL PID         ON/OFF
O2_DS_DISBL PID         YES/NO
RO2FT1 PID         %
SHRTFT1 PID         %
SPARKADV PID         DEG
TQ_CNTRL PID         STATUS
Other PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VREF B11/E6/E8         VOLTS
VPWR B101/B102/B103         VOLTS