Pinpoint Test A: All DIMMABLE Illumination Does Not Dim
WARNING: This page is about a different car, the 2014 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- A1 CHECK THE RECORDED RESULTS FROM THE SCCM ON-DEMAND SELF-TEST
- Ignition OFF.
- Review the recorded results from the SCCM on-demand self-test.
Is DTC B1124:09 present?
- Yes : GO to A2 .
- No : GO to A4.
- A2 CHECK THE INSTRUMENT PANEL DIMMER SWITCH
- Disconnect: Instrument Panel Dimmer Switch C2298 .
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: SCCM Self-Test.
- Clear the DTCs and repeat the SCCM self-test.
Is DTC B1124:09 still present?
- Yes : GO to A3 .
- No : INSTALL a new instrument panel dimmer switch. REFER to INSTRUMENT PANEL DIMMER SWITCH . TEST the system for normal operation.
- A3 CHECK THE INSTRUMENT PANEL DIMMER SWITCH INPUT CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: SCCM C2414A .
- Measure the resistance between the instrument panel dimmer switch, harness side and ground as follows:
Connector-Pin Circuit C2298-2 VLN36 (GY/OG) C2298-3 CLN55 (YE/VT) C2298-7 CLN56 (BN/VT)
Are the resistances greater than 10, 000 ohms?
- Yes : GO to A9.
- No : REPAIR the circuit in question for a short to ground. CLEAR the DTCs. REPEAT the self-test.
- A4 CHECK THE INSTRUMENT PANEL DIMMER SWITCH
- Disconnect: Instrument Panel Dimmer Switch C2298 .
- Carry out the instrument panel dimmer switch component test.
Refer to OEM WIRING DIAGRAMS COMPONENT TESTING for component testing.
Is the instrument panel dimmer switch OK?
- Yes : GO to A5 .
- No : INSTALL a new instrument panel dimmer switch. REFER to INSTRUMENT PANEL DIMMER SWITCH . TEST the system for normal operation.
- A5 CHECK THE INSTRUMENT PANEL DIMMER SWITCH UP AND DOWN INPUT CIRCUITS FOR VOLTAGE
- Ignition ON.
- Measure the voltage between the instrument panel dimmer switch C2298-7 , circuit CLN56 (BN/VT), harness side and ground; and between the instrument panel dimmer switch C2298-3 , circuit CLN55 (YE/VT), harness side and ground.
Are the voltages greater than 5 volts?
- Yes : GO to A7.
- No : GO to A6 .
- A6 CHECK THE INSTRUMENT PANEL DIMMER SWITCH UP AND DOWN INPUT CIRCUITS FOR AN OPEN
- Ignition OFF.
- Disconnect: SCCM C2414A .
- Measure the resistance between the instrument panel dimmer switch C2298-7 , circuit CLN56 (BN/VT), harness side and the SCCM C2414A-19 , circuit CLN56 (BN/VT), harness side.
- Measure the resistance between the instrument panel dimmer switch C2298-3 , circuit CLN55 (YE/VT), harness side and the SCCM C2414A-6 , circuit CLN55 (YE/VT), harness side.
Are the resistances less than 5 ohms?
- Yes : GO to A9.
- No : REPAIR the circuit in question for an open. TEST the system for normal operation.
- A7 CHECK THE INSTRUMENT PANEL DIMMER SWITCH INPUT AND RETURN CIRCUITS FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: SCCM C2414A .
- Ignition ON.
- Measure the voltage between the instrument panel dimmer switch, harness side and ground as follows:
Connector-Pin Circuit C2298-2 VLN36 (GY/OG) C2298-3 CLN55 (YE/VT) C2298-4 RLN29 (WH/OG) C2298-7 CLN56 (BN/VT)
Is any voltage present?
- Yes : REPAIR the circuit in question for a short to voltage. TEST the system for normal operation.
- No : GO to A8 .
- A8 CHECK THE INSTRUMENT PANEL DIMMER SWITCH RETURN CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure the resistance between the instrument panel dimmer switch C2298-4 , circuit RLN29 (WH/OG), harness side and the SCCM C2414A-26 , circuit RLN29 (WH/OG), harness side.
Is the resistance less than 5 ohms?
- Yes : GO to A9 .
- No : REPAIR the circuit for an open. TEST the system for normal operation.
- A9 CHECK FOR CORRECT SCCM OPERATION
- Connect all disconnected connectors.
- Disconnect all the SCCM connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SCCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
Is the concern still present?
- Yes : INSTALL a new SCCM . REFER to STEERING COLUMN CONTROL MODULE (SCCM) . TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. RUN the on-demand self-test (required to clear certain DTCs). CORRECT any unresolved DTCs. CLEAR all DTCs. TEST the system for normal operation.