Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 425 (Climate Control System - General Information And Diagnostics) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> Pinpoint Test C: DTCs C1B14:11 and C1B14:12 >> PINPOINT TEST C: DTCs C1B14:11 AND C1B14:12

PINPOINT TEST C: DTCs C1B14:11 AND C1B14:12

WARNING: This page is about a different car, the 2013 Ford Mustang. However, it is still accessible from the selected car via links, so may be relevant.
  1. C1 CHECK THE SENSOR RESISTANCE 
    • Check for HVAC DTCs.
    • Is DTC C1B14:11 present? 
    • Yes  : GO to C2.
    • No  : GO to  C4.
  2. C2 CHECK CIRCUIT LH111 (BN/WH) FOR A SHORT TO GROUND 
    • Ignition OFF.
    • Disconnect: HVAC Module C294A.
    • Disconnect: HVAC Module C294B.
    • Measure the resistance between ground and HVAC module C294A-3, circuit LH111 (BN/WH), harness side.
      Fig 1: Measuring Resistance Between Ground And HVAC Module C294A-3, Circuit LH111 (BN/WH)
      G06283666Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10, 000 ohms? 
    • Yes  : GO to C3.
    • No  : REPAIR circuit LH111 (BN/WH) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  3. C3 CHECK CIRCUITS LH111 (BN/WH) AND RH111 (GY/BU) FOR A SHORT TOGETHER 
    • Measure the resistance between HVAC module C294A-3, circuit LH111 (BN/WH), harness side and HVAC module C294A-4, circuit RH111 (GY/BU), harness side.
      Fig 2: Checking Circuits LH111 (BN/WH) And RH111 (GY/BU) For Short Together
      G06283667Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 200 ohms? 
    • Yes  : GO to  C5.
    • No  : REPAIR circuits LH111 (BN/WH) and RH111 (GY/BU) for a short together. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  4. C4 CHECK CIRCUIT LH111 (BN/WH) FOR A SHORT TO VOLTAGE 
    • Ignition OFF.
    • Disconnect: HVAC Module C294A.
    • Disconnect: HVAC Module C294B.
    • Ignition ON.
    • Measure the voltage between ground and HVAC module C294A-3, circuit LH111 (BN/WH), harness side.
      Fig 3: Checking Circuit LH111 (BN/WH) For Short To Voltage
      G06257718Courtesy of FORD MOTOR CO.
    • Is any voltage present? 
    • Yes  : REPAIR circuit LH111 (BN/WH) for a short to voltage. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
    • No  : GO to C5.
  5. C5 CHECK THE HVAC MODULE CONNECTION 
    • Inspect the HVAC module connectors for:
      • corrosion.
      • pushed-out terminals.
      • damaged terminals.
    • Connect and correctly seat all the HVAC module connectors.
    • Clear the DTCs.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.