LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (Engine Controls - Description & Operation (Diesel)) >> Engine Control Components >> Turbocharger >> Turbocharger Actuator

Turbocharger Actuator

WARNING: This page is about a different car, the 2012 Ford Pickup, 2012 Ford F550 Super Duty, 2012 Ford F450 Super Duty, and 2012 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.

The turbocharger actuator is a 4-way proportional hydraulic flow control valve with a closed center position. The valve controls the linear actuator position of a closed loop hydraulic servo by charging and venting the flow on both sides of a piston. Linear displacement feedback from the actuator varies a feedback spring force to move the valve spool to the center closed position when the actuator reaches the desired position. The actuator position is dependent only on the control valve current and not on the hydraulic fluid temperature and viscosity.

Fig 1: Identifying Turbocharger Actuator
G06054106Courtesy of FORD MOTOR CO.