Pinpoint Test I: All The STOPLAMPS Are Inoperative
WARNING: This page is about a different car, the 2013 Ford F-550 Super Duty, 2013 Ford F-450 Super Duty, 2013 Ford F-350 Super Duty, and 2013 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- I1 CHECK FOR VOLTAGE TO THE STOPLAMP SWITCH
- Ignition OFF.
- Disconnect: Stoplamp Switch C278.
- Measure the voltage between the stoplamp switch C278-1, circuit SBP21 (GY/RD), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : GO to I2.
- No : VERIFY the BCM fuse 21 (10A) is OK. If OK, GO to I4. If not OK, REFER to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short.
- I2 BYPASS THE STOPLAMP SWITCH
- Connect a fused jumper wire between the stoplamp switch C278-1, circuit SBP21 (GY/RD), harness side and the stoplamp switch C278-4, circuit CCB08 (VT/WH), harness side.
- Are the stoplamps illuminated?
- Yes
: REMOVE the jumper wire. INSTALL a new stoplamp switch. REFER to STOPLAMP SWITCH .
TEST the system for normal operation.
- No : LEAVE the jumper wire connected. GO to I3.
- I3 CHECK THE STOPLAMP SWITCH SIGNAL TO THE BCM
- Disconnect: BCM C2280b.
- Measure the voltage between the BCM C2280b-28, circuit CCB08 (VT/WH), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : REMOVE the jumper wire. GO to I5.
- No : REMOVE the jumper wire. REPAIR circuit CCB08 (VT/WH) for an open. TEST the system for normal operation.
- I4 CHECK THE STOPLAMP SWITCH VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Disconnect: BCM C2280d.
- Measure the resistance between the stoplamp switch C278-1, circuit SBP21 (GY/RD), harness side and the BCM C2280d-9, circuit SBP21 (GY/RD), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to I5.
- No : REPAIR circuit SBP21 (GY/RD) for an open. TEST the system for normal operation.
- I5 CHECK FOR CORRECT BCM OPERATION
- Disconnect all the BCM connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the BCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes
: INSTALL a new BCM. REFER to
MULTIFUNCTION ELECTRONIC MODULES
.
TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.