Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close
WARNING: This page is about a different car, the 2013 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- E1 CHECK THE POWER WINDOWS
- Ignition ON.
- Verify the power windows operate.
- Do the power windows operate?
- Yes : GO to E2.
- No : REFER to WINDOWS AND GLASS, FRAMES AND MECHANISMS to diagnose the accessory delay relay circuit.
- E2 CHECK THE MOTOR/MODULE FOR INITIALIZATION
- Attempt to carry out the Roof Opening Panel Motor Initialization procedure. Refer to ROOF OPENING PANEL MOTOR INITIALIZATION .
- Is the concern still present, or does the roof opening panel motor fail to initialize?
- Yes : GO to E3.
- No : The system is operating normally at this time. The roof opening panel motor was not initialized.
- E3 CHECK THE OVERHEAD CONSOLE SWITCH
- Ignition OFF.
- Disconnect: Overhead Console Switch C912.
- Carry out the overhead console switch component test. Refer to OEM WIRING DIAGRAMS COMPONENT TESTING for component testing.
- Is the overhead console switch OK?
- Yes : GO to E4.
- No : INSTALL a new overhead console switch. REFER to ROOF OPENING PANEL CONTROL SWITCH . TEST the system for normal operation.
- E4 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR/MODULE
- Disconnect: Roof Opening Panel Motor/Module C921.
- Ignition ON.
- Measure the voltage between roof opening panel motor/module C921-3, circuit CBP32 (GN/VT), harness side and roof opening panel motor/module C921-6, circuit SBB48 (VT/RD), harness side and ground.
- Are the voltages greater than 10 volts for both measurements?
- Yes : GO to E5.
- No
: VERIFY Battery Junction Box (BJB) fuse 48 (20A) and BCM fuse 32 (15A) are OK. If OK, REPAIR circuit SBB48 (VT/RD) and/or CBP32 (GN/VT) for an open.
If not OK, REFER to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION to identify the possible causes of the circuit short. TEST the system for normal operation.
- E5 CHECK THE ROOF OPENING PANEL MOTOR/MODULE GROUND
- Ignition OFF.
- Measure the resistance between roof opening panel motor/module C921-1, circuit GD139 (BK/YE), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to E6.
- No : REPAIR the circuit. TEST the system for normal operation.
- E6 CHECK THE OVERHEAD CONSOLE SWITCH GROUND
- Measure the resistance between overhead console switch C912-12, circuit CPR39 (VT/WH), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to E8.
- No : GO to E7.
- E7 CHECK THE COMMON CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console switch C912-12, circuit CPR39 (VT/WH), harness side and roof opening panel motor/module C921-2, circuit CPR39 (VT/WH), harness side.
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new roof opening panel motor/module. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation.
- No : REPAIR the circuit. TEST the system for normal operation.
- E8 CHECK THE ROOF OPENING PANEL CONTROL CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console switch C912-8, circuit CPR40 (YE/OG), harness side and roof opening panel motor/module C921-10, circuit CPR40 (YE/OG), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to E9.
- No : REPAIR the circuit. TEST the system for normal operation.
- E9 CHECK THE ROOF OPENING PANEL CONTROL CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console switch C912-6, circuit CPR31 (VT/BN), harness side and roof opening panel motor/module C921-5, circuit CPR31 (VT/BN), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to E10.
- No : REPAIR the circuit. TEST the system for normal operation.
- E10 CHECK THE ROOF OPENING PANEL CONTROL CIRCUITS FOR A SHORT TO GROUND
- Measure the resistance between overhead console switch C912, harness side and ground using the following chart:
Overhead Console Switch Circuit C912-6 CPR31 (VT/BN) C912-3 CPR38 (WH/BU) C912-8 CPR40 (YE/OG) - Is the resistance greater than 10, 000 ohms for all measurements?
- Yes : GO to E11.
- No : REPAIR the circuit(s). TEST the system for normal operation.
- Measure the resistance between overhead console switch C912, harness side and ground using the following chart:
- E11 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION
- Disconnect all roof opening panel motor/module connectors.
- Check for:
- corrosion.
- bent pins.
- pushed-out pins.
- Connect all roof opening panel motor/module connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new roof opening panel motor/module. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation.
- No : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.