LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 271 (HVAC - Climate Control System (Service Information)) >> Description And Operation >> Air Conditioning >> Service Gauge Port Valves

Service Gauge Port Valves

WARNING: This page is about a different car, the 2013 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.

The high-pressure service gauge port valve is located on the condenser-to-evaporator line.

The low-pressure service gauge port valve is located on the evaporator outlet portion of the TXV manifold and tube assembly.

Fig 1: Identifying Service Gauge Port Valves Components
G08341958Courtesy of FORD MOTOR CO.
Item Torque Description
1 0.8 Nm (7 lb-in) Low-pressure service gauge port valve cap
2 - Low-pressure service gauge port valve
3 2.26 Nm (20 lb-in) Low-pressure Schrader-type valve
4 3.4 Nm (30 lb-in) High-pressure Schrader-type valve
5 - High-pressure service gauge port valve
6 0.8 Nm (7 lb-in) High-pressure service gauge port valve cap

The fitting is an integral part of the refrigeration line or component.