LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 221 (Automatic Transmission (6R80)) >> Diagnosis And Testing >> Diagnosis By Symptom >> Diagnostic Routines >> Other Concerns: External Leaks

Other Concerns: External Leaks

WARNING: This page is about a different car, the 2013 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
Possible Component Reference/Action
252 - ROUTINE 
Transmission Fluid   
  • Incorrect level
  • Transmission case vent - damaged, case porosity
  • REPAIR as necessary.
  • Leakage at gaskets, seals, electrical connector
  • REFER to LEAKAGE INSPECTION . Fluid Leakage in Torque Converter Area and Leak Check Test with A Black Light. REMOVE all traces of lubricant on exposed surface of the transmission. REPAIR as necessary.
Fluid Cooler Tubes   
  • Cooler tube fittings
  • Cooler tube O-rings, cooler tubes
Torque Converter   
  • Torque converter studs
  • INSTALL a new torque converter. If a new or remanufactured torque converter is installed, use the scan tool and follow the on-screen instructions and perform the Misfire Monitor Neutral Profile Correction procedure.
  • Torque converter hub seal
  • INSTALL a new torque converter hub seal.
  • Torque converter weld
  • INSTALL a new torque converter. If a new or remanufactured torque converter is installed, use the scan tool and follow the on-screen instructions and perform the Misfire Monitor Neutral Profile Correction procedure.
Transmission Case   
  • Case - leaking
  • Transmission vehicle harness connector
  • INSTALL a new transmission vehicle harness connector O-ring.
  • Transmission fluid fill plug
  • INSTALL a new transmission fluid fill plug.
  • Output shaft seal
  • Manual control lever seal
  • INSTALL a new seal.
  • Transmission fluid pan gasket
  • INSTALL a new gasket.
Fluid Pump   
  • Fluid pump O-ring
  • Fluid pump seal ring
NOTE: NVH symptoms should be identified using the diagnostic tools that are available. For a list of these tools, an explanation of their uses and a glossary of common terms, refer to NOISE, VIBRATION & HARSHNESS . Since it is possible any one of multiple systems may be the cause of a symptom, it may be necessary to use a process of elimination type of diagnostic approach to pinpoint the responsible system. If this is not the causal system for the symptom, refer back to Section 100-04 for the next likely system and continue diagnosis.