- No communication with the HVAC module
|
- HVAC module
- Communication network
|
|
- Unable to duplicate the customer concern and no DTCs present
|
- HVAC system and/or related components
|
|
|
|
- Wiring, terminals or connectors
- A/C compressor clutch air gap
|
|
- A/C evaporator temperature sensor
- A/C clutch relay
- Blower motor control
|
- For Electronic Manual Temperature Control (EMTC), if the A/C compressor cycles normally, GO to PINPOINT TEST X .
|
- Blower motor resistor
- PCM
- HVAC module
- Front Controls Interface Module (FCIM)
|
- For Dual Automatic Temperature Control (DATC), if the A/C compressor cycles normally, GO to PINPOINT TEST Z .
|
- The air inlet door is inoperative
|
- Wiring, terminals or connectors
|
|
- Air inlet mode door actuator
- Stuck or bound linkage or door
- HVAC module
- FCIM
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Wiring, terminals or connectors
|
|
- Defrost/panel/floor mode door actuator
- Stuck or bound linkage or door
- HVAC module
- FCIM
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Plugged or partially plugged heater core
- Temperature blend door(s) binding or stuck
- Temperature blend door actuator(s)
|
|
- The air conditioning (A/C) is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- A/C system discharged/low charge
- PCM
- HVAC module
- FCIM
- A/C clutch relay
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator temperature sensor
- A/C compressor clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C compressor does not cycle
|
- Wiring, terminals or connectors
- PCM
- Evaporator temperature sensor
- A/C clutch relay
- A/C compressor clutch air gap
|
|
- The air conditioning (A/C) is always on - A/C mode always commanded ON
|
- Wiring, terminals or connectors
- PCM
- FCIM
- HVAC module
|
|
- Temperature control is inoperative/does not operate correctly - EMTC
|
- Wiring, terminals or connectors
- HVAC module
- Stuck or bound linkage or door
- Temperature blend door actuator
|
|
- Temperature control is inoperative/does not operate correctly - DATC, LH
|
- Wiring, terminals or connectors
- HVAC module
|
|
- Stuck or bound linkage or door
- Temperature blend door actuator
- FCIM
|
|
- Temperature control is inoperative/does not operate correctly - DATC, RH
|
- Wiring, terminals or connectors
- HVAC module
|
|
- Stuck or bound linkage or door
- Temperature blend door actuator
- FCIM
|
|
- The blower motor is inoperative - EMTC
|
- Fuse(s)
- Wiring, terminals or connectors
- Blower motor relay
- Blower motor
- HVAC module
|
|
- The blower motor does not operate correctly - EMTC
|
- Wiring, terminals or connectors
- Blower motor resistor
- HVAC module
|
|
- The blower motor is inoperative - DATC
|
- Fuse(s)
- Wiring, terminals or connectors
- Blower motor relay
- Blower motor
- HVAC module
- Blower motor speed control
|
|
- The blower motor does not operate correctly - DATC
|
- Wiring, terminals or connectors
- Blower motor speed control
- HVAC module
- FCIM
|
|
- A/C pressure relief valve discharging
|
- High system pressure
- A/C pressure relief valve
|
- CHECK the high side system pressure. If the pressure is below the A/C pressure relief valve open pressure, REPLACE the A/C pressure relief valve. If the system pressure is above the A/C pressure relief valve open pressure, REPAIR the system for a restriction.
|