LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Focus Electric >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation, Message Center, And Warning Chimes -- Electric >> Diagnosis and Testing >> Instrumentation, Message Center and Warning Chimes >> Symptom Chart(s) >> U3003:16 >> Pinpoint Test At: U3003:16

Pinpoint Test At: U3003:16

  1. AT1 RECHECK THE INSTRUMENT PANEL CLUSTER (IPC) DIAGNOSTIC TROUBLE CODES (DTCS) 
    • Ignition ON.
    • Using a scan tool, clear the Diagnostic Trouble Codes (DTCs).
    • Wait 10 seconds.
    • Using a scan tool, perform the IPC  self-test.

    Is Diagnostic Trouble Code (DTC) U3003:16 still present? 

    1. Yes  : GO to AT2 
    2. No  : The system is operating correctly at this time. The DTC  may have been set due to a previous low battery voltage condition.
  2. AT2 CHECK FOR CHARGING SYSTEM DIAGNOSTIC TROUBLE CODES (DTCS) IN THE BODY CONTROL MODULE (BCM) 
    • Using a scan tool, perform the BCM  self-test.

    Are any charging system Diagnostic Trouble Codes (DTCs) recorded? 

    1. Yes  : REFER to: BODY CONTROL MODULE (BCM) .
    2. No  : GO to AT3 
  3. AT3 CHECK THE BATTERY CONDITION AND STATE OF CHARGE 
    • Check the battery condition and verify the battery is fully charged.

      REFER to: BATTERY .

    Is the battery OK and fully charged? 

    1. Yes  : GO to AT4 
    2. No  : CHARGE or INSTALL a new battery.

      REFER to: BATTERY .

  4. AT4 CHECK THE INSTRUMENT PANEL CLUSTER (IPC) VOLTAGE PID 
    • Measure and record the voltage at the battery.
    • Using a scan tool, view the IPC  Parameter Identifications (PIDs).
    • Monitor the IPC  voltage (MODULE_VOLT) Parameter Identification (PID)

    Is the voltage within 0.2 volt of the recorded battery voltage? 

    1. Yes  : GO to  AT7
    2. No  : GO to AT5 
  5. AT5 CHECK THE INSTRUMENT PANEL CLUSTER (IPC) VOLTAGE SUPPLY 
    • Ignition OFF.
    • Disconnect IPC  .
    • Ignition ON.
    • Measure:
      Positive Lead Measurement/Action Negative Lead
      C220-21  VOLTAGE Ground

    Is the voltage greater than 11 volts? 

    1. Yes  : GO to AT6 
    2. No  : REPAIR the circuit.
  6. AT6 CHECK THE INSTRUMENT PANEL CLUSTER (IPC) GROUND 
    • Measure:
      Positive Lead Measurement/Action Negative Lead
      C220-21  VOLTAGE C220-5 

    Is the voltage greater than 11 volts? 

    1. Yes  : GO to AT7 
    2. No  : REPAIR the circuit.
  7. AT7 CHECK FOR CORRECT INSTRUMENT PANEL CLUSTER (IPC) OPERATION 
    • Ignition OFF.
    • Disconnect and inspect the IPC  connector.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the IPC  connector. Make sure it seats and latches correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    1. Yes  : CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new IPC  .

      REFER to: INSTRUMENTATION, MESSAGE CENTER AND WARNING CHIMES .

    2. No  : The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.