Network Message Chart
MODULE NETWORK INPUT MESSAGES - FCIM
| Broadcast Message | Originating Module | Message Purpose |
|---|---|---|
| Climate control touch screen and voice requests | APIM | This message contains both the climate control system voice commands as well as all climate control system touch screen inputs. |
| Climate control status | HVAC Module | This message contains the HVAC mode status for the mode indicators. |
MODULE NETWORK INPUT MESSAGES - APIM
| Broadcast Message | Originating Module | Message Purpose |
|---|---|---|
| Climate control status | HVAC Module | This message contains the HVAC climate control settings for the touch screen display. |
MODULE NETWORK INPUT MESSAGES - HVAC MODULE
| Broadcast Message | Originating Module | Message Purpose |
|---|---|---|
| Climate control requests (gateway) | FCIM | This message contains all climate control system controls requests except blower motor speed. |
| Climate control seat requests (gateway) | FCIM | This message contains the climate control system controls request for blower motor speed. |