- The auxiliary HVAC functions are inoperative/do not operate correctly from touch screen only
|
- Communication network
- FDIM
|
|
- The auxiliary blower motor is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- Auxiliary blower motor relay
- Auxiliary blower motor speed control
- Auxiliary blower motor
- HVAC module
|
|
- The auxiliary blower motor does not operate correctly using both the front and rear auxiliary controls
|
- Wiring, terminals or connectors
- Auxiliary blower motor relay
- Auxiliary blower motor speed control
- HVAC module
|
|
- The auxiliary blower motor does not operate correctly using the rear auxiliary controls only
|
- Wiring, terminals or connectors
- Rear auxiliary control assembly
- HVAC module
|
|
- The auxiliary temperature control is inoperative or does not operate correctly using both the front and rear auxiliary controls
|
- Wiring, terminals or connectors
- Auxiliary blend door actuator
- HVAC module
|
|
- The auxiliary temperature control is inoperative or does not operate correctly using the rear auxiliary controls only
|
- Wiring, terminals or connectors
- Rear auxiliary control assembly
- HVAC module
|
|
- The auxiliary mode control is inoperative or does not operate correctly using both the front and rear auxiliary controls
|
- Wiring, terminals or connectors
- Auxiliary mode door actuator
- HVAC module
|
|
- The auxiliary mode control is inoperative or does not operate correctly using the rear auxiliary controls only
|
- Wiring, terminals or connectors
- Rear auxiliary control assembly
- HVAC module
|
|
- The auxiliary temperature, mode and blower motor controls are inoperative or do not operate correctly using the rear auxiliary controls only
|
- Wiring, terminals or connectors
- Rear auxiliary control assembly
- HVAC module
|
|