LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Explorer Limited, 3.5 8, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 5 (Engine Controls - Reference Values (Except Diesel & Hybrid)) >> Typical Diagnostic Reference Values >> 3.7L 4V Taurus

3.7L 4V Taurus

WARNING: This page does not describe the selected car, but rather 25 other vehicles, including the 2013 Lincoln Navigator, 2013 Lincoln MKZ, 2013 Lincoln MKX, 2013 Lincoln MKT, and 2013 Lincoln MKS. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying PCM Connector - 190 Pin (3.7L 4V Taurus)
G06054072Courtesy of FORD MOTOR CO.
SENSORS/INPUTS - 3.7L 4V TAURUS

Sensors/Inputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
BOO1 B13 OFF OFF OFF OFF ON/OFF
AAT B17 19 (66.20) 18 (64.40) 20 (68) 19 (66.20) DEG C (DEG F)
AAT_V B17 3.05 3.06 2.97 3.02 VOLTS
APP1 B28 0.75 0.75 1.05 1.20 VOLTS
APP2 B29 0.37 0.37 0.53 0.60 VOLTS
FPM B32 60.31 59.67 59.67 60.31 %
MAF B40 0 3.52 11.78 29.37 g/s/kHz
MAF_HZ B40 0.70 1.72 2.96 4.23 kHz
BOO2 B46 OFF OFF OFF OFF ON/OFF
IAT B47 2.81/28 (82.40) 3/24 (75.20) 3.25/19 (66.20) 3.21/20 (68) VOLTS/DEG C (DEG F)
B+ B62 12.16 14.27 14.27 14.22 VOLTS
FTP B65 2.66/0.07 (0.01) 2.66/0.07 (0.01) 2.39/-0.34 (-0.05) 1.72/-1.59 (-0.23) VOLTS/kPa (PSI)
FTP_H2O B65 0.28 0.28 -1.59 -6.34 in-H 2 O
O2S11_CUR E23 (I) switching (C) switching (C) switching (C) uA
O2S21_CUR E24 (I) switching (C) switching (C) switching (C) uA
CHT E39 0.67/85 (185) 0.66/86 (186.80) 3.44/94 (201.20) 3.72/87 (188.60) VOLTS/DEG C (DEG F)
TP1 E41 4.10/17.64 4.32/13.33 4.20/15.68 4.12/17.25 VOLTS/%
KNOCK_1 E43 170 174 172 237 N/A
TP2 E58 1.21/23.92 0.76/15.29 1/20 1.16/23.13 VOLTS/%
KNOCK_2 E60 224 200 200 202 N/A
O2S12 T29 0.94 0.93 0.65 0.67 VOLTS
O2S22 T40 0.93 0.93 0.23 0.70 VOLTS
HTRCM22 T48 0 622 634 634 mA
HTRCM12 T49 0 630 634 634 mA
AC_REQ PID NO NO NO NO YES/NO
APP PID 0 0 8.50 13.50 %
APP_MAXDIFF PID 0 0 0 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
APP1 (APP_D) PID 14.90 14.90 20.78 23.92 %
APP2 (APP_E) PID 7.45 7.45 10.58 11.76 %
BARO PID 92.94 (13.48)/150.62/373.36 92.94 (13.48)/150.62/373.36 92.94 (13.48)/150.62/373.36 93.98 (13.63)/151.53/377.37 kPa (PSI)/Hz/in-H 2 O
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
BRKOVRD_POSS PID 8 8 9 9 NUMERIC VALUE
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 10.99 (6.83) 10.99 (6.83) 10.99 (6.83) 12.49 (7.76) KM (MILES)
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0/0:1 1/14.68:1 1.02/14.86:1 1.01/14.72:1 RATIO
EQ_RAT21 PID 0/0:1 1.01/14.71:1 0.98/14.28:1 1/14.57:1 RATIO
ETC_ACT PID 9.80 1.96 9.80 10.98 DEG
ETC_TRIM PID 0.04 0.15 0.34 0.34 DEG
FF_INF PID 9.80 9.80 9.80 9.80 %
FF_LRND PID NO NO YES YES YES/NO
FLI PID 52.54 51.76 43.92 49.02 %
IACKAM2 PID -0.14 -0.10 -0.56 -0.56 NUMERIC VALUE
INJPWR_M PID 12.30 14.18 14.20 14.18 VOLTS
LOAD PID 0 36.07 42.35 72.54 %
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 0 0 COUNT
O2S11_IMPED PID 5 0.09 0.09 0.09 VOLTS
O2S11_READY PID NO YES YES YES YES/NO
O2S11_TR PID 29.40 29.40 29.40 29.40 Kohm
O2S21_IMPED PID 5 0.09 0.09 0.09 VOLTS
O2S21_READY PID NO YES YES YES YES/NO
O2S21_TR PID 23.60 23.60 23.60 23.60 Kohm
RPM PID 0 595.75 1343 1668.50 RPM
SYNC PID YES YES YES YES YES/NO
TP1_LRN_TRIM PID 6.87 6.87 6.87 6.87 DEG
TP2_LRN_TRIM PID 7 7 7 7 DEG
TPMODE PID PT CT PT PT CLOSED/PART/WIDE OPEN THROTTLE
VCT_EXH_ACT1 PID 0 0 17.06 0 DEG
VCT_EXH_ACT2 PID 0 0 17.37 0.68 DEG
VCT_EXH_DIF1 PID 0 0 -1.06 0 DEG
VCT_EXH_DIF2 PID 0 0 -1.25 -0.68 DEG
VCT_INT_ACT1 PID 0 0 -0.18 -33.93 DEG
VCT_INT_ACT2 PID 0 -0.06 -9.93 -34.06 DEG
VCT_INT_DIF1 PID 0 -0.06 -0.18 -1.06 DEG
VCT_INT_DIF2 PID 0 0.18 -0.18 -0.87 DEG
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h / MPH
ACTUATORS/OUTPUTS - 3.7L 4V TAURUS

Actuators/Outputs PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
HFC B18 OFF OFF OFF OFF ON/OFF
FP B19 75/OFF 36.01/ON 36.09/ON 36.05/ON %/ON/OFF
EVAPCV B20 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
LFC B34 OFF OFF ON OFF ON/OFF
VCT_EXH_DC2 E18 0 0 38.26 0 %
EVAPCP E32 0 10.98 21.71 82.93 %
VCT_EXH_DC1 E52 0 0 39.79 0 %
VCT_INT_DC1 E67 0 0 43.65 42.83 %
VCT_INT_DC2 E68 0 0 46.62 45.47 %
HTR11 E69 OFF ON ON ON ON/OFF
O2S11_HTR E69 22.35 39.21 33.72 29.02 %
HTR21 E70 OFF ON ON ON ON/OFF
O2S21_HTR E70 22.35 31.76 32.94 31.76 %
HTR22 T48 OFF ON ON ON ON/OFF
HTR12 T49 OFF ON ON ON ON/OFF
ETC [TAC_PCT] PID         %
EVAP020C PID NO NO NO NO YES/NO
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FUELSYS PID OPEN LOOP CLOSED LOOP OL-DRIVE CLOSED LOOP OPEN/CLOSED LOOP
GRILL_A_CMD PID 0/CLOSED 0/CLOSED 0/CLOSED 0/CLOSED %/OPEN/CLOSED
GRILL_A_INF PID 0 0 0 0 %
GRILL_CMDCAL PID NO NO NO NO YES/NO
IACTRIM PID 0 0 0 0 NUMERIC VALUE
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MIL PID OFF OFF OFF OFF ON/OFF
O2_DS_DISBL PID YES YES NO NO YES/NO
RO2FT1 PID 0 -0.89 -1.33 1.68 %
RO2FT2 PID 0 -0.89 -1.35 1.68 %
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SPARKADV PID 23.50 13.25 36.50 34 DEG
TQ_CNTRL PID NONE REQUESTED NONE REQUESTED NONE REQUESTED NONE REQUESTED STATUS
OTHER - 3.7L 4V TAURUS

Other PCM Pin/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VREF B52/B61/B66/E35/E57 5 5 5 5 VOLTS
VPWR B67/B68 VBAT VBAT VBAT VBAT VOLTS