Torque Converter Hydraulic Circuits

WARNING: This page is about a different car, the 2013 Ford Explorer. However, it is still accessible from the selected car via links, so may be relevant.

The PCM controls the TCC  solenoid. The TCC  solenoid applies hydraulic pressure to the TCC  control and regulator apply valves through the TCC  SOL SIG circuit. Regulated DRIVE 2 pressure from the multiplex shift valve is directed to the TCC  control valve by the TCC  regulator apply valve through the REG APPLY circuit. The TCC  control valve directs pressure from the REG APPLY circuit to the TCC  APPLY circuit to apply the clutch.

The transmission fluid returns to the TCC  control valve through the TCC  RELEASE hydraulic circuit. The TCC control valve opens the TCC  RELEASE circuit to exhaust, so the TCC  RELEASE circuit is not pressurized when the TCC  is applied.

G06259885

When the TCC  is released, The TCC  solenoid does not apply hydraulic pressure to the TCC  control or regulator apply valves. The TCC  control valve, in this position, directs hydraulic pressure from the CONV FD circuit to the torque converter through the TCC  RELEASE hydraulic circuit and it returns to the TCC  control valve through the TCC  APPLY circuit.

G06259886