Pinpoint Test
- CHECK THE LH DOOR LOCK CONTROL SWITCH
- Disconnect: LH Door Lock Control Switch.
- Using a scan tool, clear the BCM DTCs .
- Using a scan tool, perform the BCM self-test.
Is DTC B126A:01 retrieved?
- Yes: LEAVE the switch disconnected. GO to 2 .
- No: INSTALL a new LH door lock control switch. REFER to Door Lock Control Switch .
- CHECK THE RH DOOR LOCK CONTROL SWITCH
- Disconnect: RH Door Lock Control Switch.
- Using a scan tool, clear the BCM DTCs .
- Using a scan tool, perform the BCM self-test.
Is DTC B126A:01 retrieved again?
- Yes: LEAVE the switch disconnected. GO to 3 .
- No: INSTALL a new RH door lock control switch. REFER to Door Lock Control Switch .
- CHECK THE LOCK INPUT CIRCUIT OR THE UNLOCK INPUT CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: BCM C2280C.
- Measure:
RH Door Lock Control Switch Ground C605 Ground Pin Circuit Measurement / Action Pin Circuit 4 CPK19 (BU/GN) - Ground 2 CPK23 (YE/VT) - Ground
Are the resistances greater than 10, 000 ohms?
- Yes: GO to 4 .
- No: REPAIR the affected circuit.
- CHECK FOR CORRECT BCM OPERATION
- Ignition OFF.
- Disconnect and inspect all BCM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all BCM connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes: CHECK OASIS for any applicable TSBs . If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new BCM. REFER to BODY CONTROL MODULE (BCM) - WITHOUT INTELLIGENT ACCESS (IA) .
- No: The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.