Pinpoint Test
- CHECK THE BCM DTCs
FROM THE SELF-TEST
- Using a scan tool, perform the BCM self-test.
Is DTC B126A:01 present?
- Yes: REFER to Diagnostic Routine E: B126A:01 .
- No: GO to 2 .
- VERIFY THE OPERATION OF BOTH DOOR LOCK CONTROL SWITCHES
- Ignition OFF.
- Press the lock and unlock buttons of both door lock control switches while observing the door lock operation.
Do the door locks operate only one way from both switches?
- Yes: GO to 5.
- No: GO to 3 .
- CHECK THE LOCK INPUT CIRCUIT FOR AN OPEN (SINGLE SWITCH INOPERATIVE)
- Disconnect: Suspect Door Lock Control Switch.
- Unlock the doors from the working door lock control switch.
- For the LH door lock control switch, connect a fused jumper wire:
Door Lock Control Switch Door Lock Control Switch C505 C505 Pin Circuit Measurement / Action Pin Circuit 1 CPK19 (BU/GN) 2 GD233 (BK) - For the RH door lock control switch, connect a fused jumper wire:
Door Lock Control Switch Door Lock Control Switch C605 C605 Pin Circuit Measurement / Action Pin Circuit 4 CPK19 (BU/GN) 3 GD348 (BK/YE)
Do the doors lock with the jumper wire?
- Yes: REMOVE the jumper wire. GO to 4 .
- No: REMOVE the jumper wire. REPAIR the circuit for an open.
- CHECK THE UNLOCK INPUT CIRCUIT FOR AN OPEN (SINGLE SWITCH INOPERATIVE)
A00517600
- For the LH door lock control switch, connect a fused jumper wire:
Door Lock Control Switch Door Lock Control Switch C505 C505 Pin Circuit Measurement / Action Pin Circuit 3 CPK23 (YE/VT) 2 GD233 (BK) - For the RH door lock control switch, connect a fused jumper wire:
Door Lock Control Switch Door Lock Control Switch C605 C605 Pin Circuit Measurement / Action Pin Circuit 2 CPK23 (YE/VT) 3 GD348 (BK/YE)
Do the unlock with the jumper wire?
- Yes: REMOVE the jumper wire. INSTALL a new door lock control switch. REFER to Door Lock Control Switch .
- No: Remove the jumper wire. REPAIR the circuit for an open.
- For the LH door lock control switch, connect a fused jumper wire:
- CHECK THE LOCK INPUT OR THE UNLOCK INPUT CIRCUIT FOR AN OPEN (BOTH SWITCHES INOPERATIVE)
- Disconnect LH Door Lock Control Switch C505.
- Disconnect BCM C2280C.
- If the doors do not lock, measure:
BCM LH Door Lock Control Switch C2280C C505 Pin Circuit Measurement / Action Pin Circuit 6 CPK19 (BU/GN) 1 CPK19 (BU/GN) - If the doors do not unlock, measure:
BCM LH Door Lock Control Switch C2280C C505 Pin Circuit Measurement / Action Pin Circuit 8 CPK23 (YE/VT) 3 CPK23 (YE/VT)
Is the resistance less than 3 ohms?
- Yes: GO to 6 .
- No: REPAIR the affected circuit for an open.
- CHECK FOR CORRECT BCM OPERATION
- Ignition OFF.
- Disconnect and inspect all BCM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all BCM connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes: CHECK OASIS for any applicable TSBs . If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new BCM. REFER to BODY CONTROL MODULE (BCM) - WITHOUT INTELLIGENT ACCESS (IA) .
- No: The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.